Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 7.866 kW
09/13/2025 21:40 (1935 days) Production Consumption NET Usage
Now 0.000 kW 7.866 kW 7.866 kW
Today 22.447 kWh (1.035 kW) 22.746 kWh (1.049 kW) 0.299 kWh (0.014 kW)
  - This Week 148.841 kWh (21.560 kWh/day) 107.410 kWh (15.559 kWh/day) -41.431 kWh (-6.001 kWh/day)
  - This Month 285.769 kWh (22.147 kWh/day) 303.135 kWh (23.493 kWh/day) 17.366 kWh (1.346 kWh/day)
  - This Year 4.793 MWh (18.730 kWh/day) 5.474 MWh (21.390 kWh/day) 0.681 MWh (2.660 kWh/day)
Yesterday 20.907 kWh (0.870 kW) 16.569 kWh (0.690 kW) -4.338 kWh (-0.181 kW)
Last 7 Days 141.741 kWh (20.247 kWh/day) 152.074 kWh (21.723 kWh/day) 10.333 kWh (1.476 kWh/day)
Last 30 Days 686.605 kWh (22.887 kWh/day) 731.787 kWh (24.393 kWh/day) 45.182 kWh (1.506 kWh/day)
Last One Year 6.275 MWh (17.192 kWh/day) 7.087 MWh (19.417 kWh/day) 0.812 MWh (2.225 kWh/day)
Lifetime Since PTO 34.244 MWh (17.689 kW/day) 37.426 MWh (19.333 kW/day) 3.182 MWh (1.644 kW/day)
Lifetime Since Install 34.278 MWh 38.006 MWh 3.728 MWh
Voltage/Current 249.0 V / 0.0 A 248.9 V / 31.6 A 248.9 V / 31.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/26/2021 20:37 (14.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 16.320 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.294 1.135 2.217 12.494 0.000 kW
1.089 kWh
0.000 kW
6.536 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.084 2.163 12.011
03 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.107 2.218 12.113
04 - 202232****** IQ7+ [0] ---- 0.000 0.295 1.101 2.222 12.203
05 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.011 2.085 11.099
06 - 202245****** IQ7+M [0] ---- 0.000 0.294 1.098 2.164 12.136
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.296 0.982 2.041 10.964 0.000 kW
1.012 kWh
0.000 kW
5.059 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.292 1.011 2.066 11.256
09 - 202217****** IQ7+ [0] ---- 0.000 0.293 1.015 2.070 11.167
10 - 202244****** IQ7+M [0] ---- 0.000 0.293 1.029 2.082 11.407
11 - 202224****** IQ7+M [0] ---- 0.000 0.296 1.022 2.089 11.438
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.272 1.179 2.008 12.503 0.000 kW
1.181 kWh
0.000 kW
4.725 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.277 1.167 1.947 12.127
14 - 202216****** IQ7+ [0] ---- 0.000 0.280 1.195 2.023 12.550
15 - 202245****** IQ7+M [0] ---- 0.000 0.279 1.183 1.996 12.363
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 526.2 Ah (26.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.7 % State Of Health 100.0 %
Run Time 14d 14h 48m to empty Report Date 2021-06-26 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt1_0.png". Check that the process running PHP has enough permission.