Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.538 kW
07/03/2026 20:49 (2228 days) Production Consumption NET Usage
Now 0.225 kW 2.763 kW 2.538 kW
Today 32.366 kWh (1.553 kW) 37.051 kWh (1.778 kW) 4.685 kWh (0.225 kW)
  - This Week 175.240 kWh (29.865 kWh/day) 197.189 kWh (33.606 kWh/day) 21.949 kWh (3.741 kWh/day)
  - This Month 93.639 kWh (32.646 kWh/day) 123.049 kWh (42.899 kWh/day) 29.410 kWh (10.253 kWh/day)
  - This Year 3.703 MWh (20.142 kWh/day) 3.410 MWh (18.545 kWh/day) -0.294 MWh (-1.597 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 185.258 kWh (26.465 kWh/day) 216.349 kWh (30.907 kWh/day) 31.091 kWh (4.442 kWh/day)
Last 30 Days (06/03/2026) 856.556 kWh (28.552 kWh/day) 804.106 kWh (26.804 kWh/day) -52.450 kWh (-1.748 kWh/day)
Last One Year 6.723 MWh (18.418 kWh/day) 7.756 MWh (21.250 kWh/day) 1.034 MWh (2.832 kWh/day)
Lifetime Since PTO 39.269 MWh (17.618 kW/day) 42.921 MWh (19.257 kW/day) 3.651 MWh (1.638 kW/day)
Lifetime Since Install 39.303 MWh 43.501 MWh 4.198 MWh
Voltage/Current 248.0 V / 0.9 A 247.9 V / 11.1 A 248.0 V / 10.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/10/2022 22:12 (12.7 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 13.884 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.297 0.937 1.355 6.908 0.000 kW
0.894 kWh
0.000 kW
5.362 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.293 0.862 1.266 6.523
03 - 202224****** IQ7+M [0] ---- 0.000 0.294 0.965 1.360 6.917
04 - 202232****** IQ7+ [0] ---- 0.000 0.296 0.937 1.305 6.722
05 - 202244****** IQ7+M [0] ---- 0.000 0.295 0.825 1.287 6.552
06 - 202245****** IQ7+M [0] ---- 0.000 0.296 0.834 1.248 6.443
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.295 0.790 1.345 6.556 0.000 kW
0.835 kWh
0.000 kW
4.173 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.297 0.842 1.314 6.641
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 0.828 1.256 6.525
10 - 202244****** IQ7+M [0] ---- 0.000 0.294 0.848 1.378 6.703
11 - 202224****** IQ7+M [0] ---- 0.000 0.296 0.865 1.379 6.787
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.285 1.088 1.119 6.166 0.000 kW
1.087 kWh
0.000 kW
4.350 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.284 1.080 1.074 6.027
14 - 202216****** IQ7+ [0] ---- 0.000 0.286 1.098 1.134 6.241
15 - 202245****** IQ7+M [0] ---- 0.000 0.281 1.084 1.119 6.147
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.14 V Current/Power -3.58 A (-0.190 kW)
Remain Capacity/Energy 417.0 Ah (21.4 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 69.5 % State Of Health 100.0 %
Run Time 4d 20h 28m to empty Report Date 2022-04-10 23:52
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.