Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.321 kW
09/13/2025 22:03 (1935 days) Production Consumption NET Usage
Now 0.000 kW 0.321 kW 0.321 kW
Today 22.447 kWh (1.018 kW) 23.258 kWh (1.054 kW) 0.811 kWh (0.037 kW)
  - This Week 148.841 kWh (21.511 kWh/day) 107.922 kWh (15.597 kWh/day) -40.919 kWh (-5.914 kWh/day)
  - This Month 285.769 kWh (22.120 kWh/day) 303.647 kWh (23.504 kWh/day) 17.878 kWh (1.384 kWh/day)
  - This Year 4.793 MWh (18.729 kWh/day) 5.474 MWh (21.391 kWh/day) 0.681 MWh (2.662 kWh/day)
Yesterday 20.907 kWh (0.870 kW) 16.569 kWh (0.690 kW) -4.338 kWh (-0.181 kW)
Last 7 Days 141.741 kWh (20.247 kWh/day) 152.074 kWh (21.723 kWh/day) 10.333 kWh (1.476 kWh/day)
Last 30 Days 686.605 kWh (22.887 kWh/day) 731.787 kWh (24.393 kWh/day) 45.182 kWh (1.506 kWh/day)
Last One Year 6.275 MWh (17.192 kWh/day) 7.087 MWh (19.417 kWh/day) 0.812 MWh (2.225 kWh/day)
Lifetime Since PTO 34.244 MWh (17.689 kW/day) 37.426 MWh (19.333 kW/day) 3.182 MWh (1.644 kW/day)
Lifetime Since Install 34.278 MWh 38.006 MWh 3.728 MWh
Voltage/Current 251.8 V / 0.0 A 251.9 V / 1.3 A 251.8 V / 1.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/06/2021 20:44 (14.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 31.785 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.295 2.253 2.299 8.948 0.000 kW
2.145 kWh
0.000 kW
12.868 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.291 2.155 2.198 8.661
03 - 202224****** IQ7+M [0] ---- 0.000 0.295 2.154 2.196 8.765
04 - 202232****** IQ7+ [0] ---- 0.000 0.295 2.178 2.219 8.755
05 - 202244****** IQ7+M [0] ---- 0.000 0.291 1.958 1.997 8.218
06 - 202245****** IQ7+M [0] ---- 0.000 0.289 2.170 2.218 8.689
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.287 1.972 1.997 7.892 0.000 kW
2.025 kWh
0.000 kW
10.125 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.285 2.029 2.056 8.152
09 - 202217****** IQ7+ [0] ---- 0.000 0.285 2.011 2.037 8.111
10 - 202244****** IQ7+M [0] ---- 0.000 0.286 2.054 2.092 8.340
11 - 202224****** IQ7+M [0] ---- 0.000 0.285 2.058 2.099 8.353
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.271 2.234 2.271 8.515 0.000 kW
2.198 kWh
0.000 kW
8.792 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.268 2.151 2.173 8.288
14 - 202216****** IQ7+ [0] ---- 0.000 0.269 2.223 2.257 8.577
15 - 202245****** IQ7+M [0] ---- 0.000 0.264 2.185 2.219 8.456
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 523.8 Ah (26.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.3 % State Of Health 100.0 %
Run Time 14d 13h 11m to empty Report Date 2021-06-06 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.