Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.273 kW
05/16/2026 06:21 (2180 days) Production Consumption NET Usage
Now 0.154 kW -0.119 kW -0.273 kW
Today 0.054 kWh (0.008 kW) 0.277 kWh (0.043 kW) 0.223 kWh (0.035 kW)
  - This Week 150.877 kWh (24.080 kWh/day) 75.924 kWh (12.117 kWh/day) -74.953 kWh (-11.962 kWh/day)
  - This Month 368.952 kWh (24.169 kWh/day) 193.061 kWh (12.647 kWh/day) -175.891 kWh (-11.522 kWh/day)
  - This Year 2.322 MWh (17.166 kWh/day) 2.253 MWh (16.654 kWh/day) -0.069 MWh (-0.512 kWh/day)
Yesterday 21.295 kWh (0.887 kW) 9.495 kWh (0.396 kW) -11.800 kWh (-0.492 kW)
Last 7 Days 160.475 kWh (22.925 kWh/day) 89.451 kWh (12.779 kWh/day) -71.024 kWh (-10.146 kWh/day)
Last 30 Days (04/16/2026) 683.174 kWh (22.772 kWh/day) 393.835 kWh (13.128 kWh/day) -289.339 kWh (-9.645 kWh/day)
Last One Year 6.338 MWh (17.364 kWh/day) 7.787 MWh (21.335 kWh/day) 1.449 MWh (3.971 kWh/day)
Lifetime Since PTO 37.888 MWh (17.378 kW/day) 41.764 MWh (19.155 kW/day) 3.876 MWh (1.778 kW/day)
Lifetime Since Install 37.922 MWh 42.344 MWh 4.422 MWh
Voltage/Current 250.9 V / 0.6 A 250.9 V / -0.5 A 250.9 V / -1.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/26/2022 23:23 (9.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 17.466 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.242 1.275 0.519 5.618 0.000 kW
1.250 kWh
0.000 kW
7.499 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.233 1.217 0.489 5.273
03 - 202224****** IQ7+M [5] VCOP 0.000 0.239 1.274 0.519 5.583
04 - 202232****** IQ7+ [5] VCOP 0.000 0.238 1.255 0.501 5.434
05 - 202244****** IQ7+M [5] VCOP 0.000 0.237 1.259 0.497 5.498
06 - 202245****** IQ7+M [5] VCOP 0.000 0.233 1.218 0.480 5.307
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.505 0.579 6.622 0.000 kW
1.521 kWh
0.000 kW
7.605 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.328 0.577 6.251
09 - 202217****** IQ7+ [5] VCOP 0.000 0.298 1.638 0.606 6.850
10 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.598 0.597 6.707
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.537 0.591 6.655
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.119 0.535 0.374 2.846 0.000 kW
0.591 kWh
0.000 kW
2.362 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.120 0.615 0.380 3.103
14 - 202216****** IQ7+ [5] VCOP 0.000 0.121 0.615 0.387 3.129
15 - 202245****** IQ7+M [5] VCOP 0.000 0.119 0.597 0.381 3.064
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.20 V Current/Power -2.10 A (-0.112 kW)
Remain Capacity/Energy 504.0 Ah (25.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 84.0 % State Of Health 100.0 %
Run Time 10d 0h 0m to empty Report Date 2022-01-26 23:54
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.