Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.690 kW
09/13/2025 21:24 (1935 days) Production Consumption NET Usage
Now 0.000 kW 0.690 kW 0.690 kW
Today 22.447 kWh (1.048 kW) 22.195 kWh (1.036 kW) -0.252 kWh (-0.012 kW)
  - This Week 148.841 kWh (21.595 kWh/day) 106.859 kWh (15.504 kWh/day) -41.982 kWh (-6.091 kWh/day)
  - This Month 285.769 kWh (22.166 kWh/day) 302.584 kWh (23.471 kWh/day) 16.815 kWh (1.304 kWh/day)
  - This Year 4.793 MWh (18.731 kWh/day) 5.473 MWh (21.389 kWh/day) 0.680 MWh (2.658 kWh/day)
Yesterday 20.907 kWh (0.870 kW) 16.569 kWh (0.690 kW) -4.338 kWh (-0.181 kW)
Last 7 Days 141.741 kWh (20.247 kWh/day) 152.074 kWh (21.723 kWh/day) 10.333 kWh (1.476 kWh/day)
Last 30 Days 686.605 kWh (22.887 kWh/day) 731.787 kWh (24.393 kWh/day) 45.182 kWh (1.506 kWh/day)
Last One Year 6.275 MWh (17.192 kWh/day) 7.087 MWh (19.417 kWh/day) 0.812 MWh (2.225 kWh/day)
Lifetime Since PTO 34.244 MWh (17.689 kW/day) 37.425 MWh (19.332 kW/day) 3.181 MWh (1.643 kW/day)
Lifetime Since Install 34.278 MWh 38.005 MWh 3.727 MWh
Voltage/Current 251.1 V / 0.0 A 251.1 V / 2.7 A 251.1 V / 2.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/19/2021 20:13 (14.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 31.010 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.281 2.172 2.149 13.507 0.000 kW
2.084 kWh
0.000 kW
12.506 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.276 2.084 2.058 12.924
03 - 202224****** IQ7+M [0] ---- 0.000 0.280 2.102 2.076 13.063
04 - 202232****** IQ7+ [0] ---- 0.000 0.281 2.137 2.104 13.294
05 - 202244****** IQ7+M [0] ---- 0.000 0.276 1.918 1.891 11.780
06 - 202245****** IQ7+M [0] ---- 0.000 0.275 2.092 2.068 12.997
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.280 1.969 1.879 11.977 0.000 kW
2.000 kWh
0.000 kW
9.998 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.279 2.003 1.953 12.133
09 - 202217****** IQ7+ [0] ---- 0.000 0.280 1.985 1.916 12.132
10 - 202244****** IQ7+M [0] ---- 0.000 0.278 2.020 1.972 12.311
11 - 202224****** IQ7+M [0] ---- 0.000 0.278 2.021 1.987 12.310
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.259 2.154 2.143 14.109 0.000 kW
2.126 kWh
0.000 kW
8.506 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.259 2.072 2.073 13.702
14 - 202216****** IQ7+ [0] ---- 0.000 0.261 2.154 2.133 14.087
15 - 202245****** IQ7+M [0] ---- 0.000 0.258 2.125 2.101 13.906
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -0.90 A (-47 W)
Remain Capacity/Energy 524.7 Ah (26.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.5 % State Of Health 100.0 %
Run Time 24d 7h 0m to empty Report Date 2021-05-19 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.