Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.191 kW
07/04/2026 00:30 (2229 days) Production Consumption NET Usage
Now 0.226 kW 0.417 kW 0.191 kW
Today 0.122 kWh (0.226 kW) 0.546 kWh (1.012 kW) 0.424 kWh (0.786 kW)
  - This Week 176.074 kWh (29.241 kWh/day) 202.463 kWh (33.623 kWh/day) 26.389 kWh (4.382 kWh/day)
  - This Month 94.473 kWh (31.261 kWh/day) 128.323 kWh (42.461 kWh/day) 33.850 kWh (11.201 kWh/day)
  - This Year 3.704 MWh (20.130 kWh/day) 3.415 MWh (18.558 kWh/day) -0.289 MWh (-1.572 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 186.092 kWh (26.585 kWh/day) 219.350 kWh (31.336 kWh/day) 33.258 kWh (4.751 kWh/day)
Last 30 Days (06/04/2026) 856.228 kWh (28.541 kWh/day) 807.569 kWh (26.919 kWh/day) -48.659 kWh (-1.622 kWh/day)
Last One Year 6.724 MWh (18.421 kWh/day) 7.758 MWh (21.254 kWh/day) 1.034 MWh (2.834 kWh/day)
Lifetime Since PTO 39.270 MWh (17.618 kW/day) 42.926 MWh (19.258 kW/day) 3.656 MWh (1.640 kW/day)
Lifetime Since Install 39.304 MWh 43.506 MWh 4.202 MWh
Voltage/Current 250.7 V / 0.9 A 250.6 V / 1.7 A 250.7 V / 0.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 02/20/2022 23:50 (10.6 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 14.688 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.297 1.159 0.686 4.122 0.000 kW
1.122 kWh
0.000 kW
6.734 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.297 0.822 0.639 4.027
03 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.369 0.679 4.372
04 - 202232****** IQ7+ [0] ---- 0.000 0.300 1.200 0.666 4.371
05 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.129 0.666 6.337
06 - 202245****** IQ7+M [0] ---- 0.000 0.298 1.054 0.640 6.204
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.298 1.376 0.448 6.746 0.000 kW
1.047 kWh
0.000 kW
5.233 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.002 0.332 5.520
09 - 202217****** IQ7+ [0] ---- 0.000 0.300 1.041 0.651 8.347
10 - 202244****** IQ7+M [0] ---- 0.000 0.298 0.912 0.625 8.307
11 - 202224****** IQ7+M [0] ---- 0.000 0.298 0.902 0.645 8.229
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.211 0.642 0.614 3.137 0.000 kW
0.680 kWh
0.000 kW
2.721 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.215 0.756 0.608 2.520
14 - 202216****** IQ7+ [0] ---- 0.000 0.218 0.725 0.620 2.528
15 - 202245****** IQ7+M [0] ---- 0.000 0.214 0.598 0.613 2.537
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.28 V Current/Power -0.60 A (-31 W)
Remain Capacity/Energy 522.9 Ah (26.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.1 % State Of Health 100.0 %
Run Time 36d 7h 29m to empty Report Date 2022-02-20 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack