Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.121 kW
05/16/2026 08:23 (2180 days) Production Consumption NET Usage
Now 0.922 kW -0.199 kW -1.121 kW
Today 1.215 kWh (0.145 kW) 0.689 kWh (0.082 kW) -0.526 kWh (-0.063 kW)
  - This Week 152.038 kWh (23.942 kWh/day) 76.336 kWh (12.021 kWh/day) -75.702 kWh (-11.921 kWh/day)
  - This Month 370.113 kWh (24.112 kWh/day) 193.473 kWh (12.604 kWh/day) -176.640 kWh (-11.508 kWh/day)
  - This Year 2.323 MWh (17.164 kWh/day) 2.253 MWh (16.647 kWh/day) -0.070 MWh (-0.517 kWh/day)
Yesterday 21.295 kWh (0.887 kW) 9.495 kWh (0.396 kW) -11.800 kWh (-0.492 kW)
Last 7 Days 161.267 kWh (23.038 kWh/day) 88.666 kWh (12.667 kWh/day) -72.601 kWh (-10.372 kWh/day)
Last 30 Days (04/16/2026) 682.918 kWh (22.764 kWh/day) 392.345 kWh (13.078 kWh/day) -290.573 kWh (-9.686 kWh/day)
Last One Year 6.338 MWh (17.366 kWh/day) 7.786 MWh (21.332 kWh/day) 1.448 MWh (3.967 kWh/day)
Lifetime Since PTO 37.889 MWh (17.377 kW/day) 41.764 MWh (19.155 kW/day) 3.875 MWh (1.777 kW/day)
Lifetime Since Install 37.923 MWh 42.344 MWh 4.421 MWh
Voltage/Current 250.3 V / 3.7 A 250.4 V / -0.8 A 250.4 V / -4.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/09/2021 23:13 (8.9 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 8.752 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.171 0.641 0.307 4.528 0.000 kW
0.619 kWh
0.000 kW
3.711 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.168 0.601 0.281 4.301
03 - 202224****** IQ7+M [5] VCOP 0.000 0.175 0.639 0.309 4.560
04 - 202232****** IQ7+ [5] VCOP 0.000 0.172 0.625 0.303 4.444
05 - 202244****** IQ7+M [5] VCOP 0.000 0.168 0.610 0.292 4.452
06 - 202245****** IQ7+M [5] VCOP 0.000 0.166 0.597 0.288 4.292
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.202 0.643 0.312 5.121 0.000 kW
0.649 kWh
0.000 kW
3.243 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.216 0.577 0.311 4.576
09 - 202217****** IQ7+ [5] VCOP 0.000 0.207 0.705 0.317 5.453
10 - 202244****** IQ7+M [5] VCOP 0.000 0.203 0.690 0.300 5.330
11 - 202224****** IQ7+M [5] VCOP 0.000 0.203 0.627 0.319 5.047
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.102 0.445 0.258 2.348 0.000 kW
0.450 kWh
0.000 kW
1.798 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.108 0.449 0.260 2.537
14 - 202216****** IQ7+ [5] VCOP 0.000 0.109 0.456 0.267 2.567
15 - 202245****** IQ7+M [5] VCOP 0.000 0.110 0.448 0.263 2.519
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.75 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 332.1 Ah (17.0 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 55.4 % State Of Health 100.0 %
Run Time 9d 5h 24m to empty Report Date 2021-12-09 23:50
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack