Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.266 kW
07/03/2026 23:18 (2228 days) Production Consumption NET Usage
Now 0.224 kW 0.490 kW 0.266 kW
Today 32.926 kWh (1.412 kW) 41.121 kWh (1.763 kW) 8.195 kWh (0.351 kW)
  - This Week 175.800 kWh (29.442 kWh/day) 201.259 kWh (33.706 kWh/day) 25.459 kWh (4.264 kWh/day)
  - This Month 94.199 kWh (31.699 kWh/day) 127.119 kWh (42.777 kWh/day) 32.920 kWh (11.078 kWh/day)
  - This Year 3.704 MWh (20.134 kWh/day) 3.414 MWh (18.557 kWh/day) -0.290 MWh (-1.577 kWh/day)
Yesterday 35.642 kWh (1.485 kW) 43.847 kWh (1.826 kW) 8.205 kWh (0.342 kW)
Last 7 Days 185.818 kWh (26.545 kWh/day) 218.298 kWh (31.185 kWh/day) 32.480 kWh (4.640 kWh/day)
Last 30 Days (06/03/2026) 856.341 kWh (28.545 kWh/day) 806.845 kWh (26.895 kWh/day) -49.496 kWh (-1.650 kWh/day)
Last One Year 6.723 MWh (18.420 kWh/day) 7.757 MWh (21.252 kWh/day) 1.034 MWh (2.832 kWh/day)
Lifetime Since PTO 39.270 MWh (17.618 kW/day) 42.925 MWh (19.258 kW/day) 3.655 MWh (1.640 kW/day)
Lifetime Since Install 39.304 MWh 43.505 MWh 4.201 MWh
Voltage/Current 250.5 V / 0.9 A 250.4 V / 2.0 A 250.5 V / 1.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/23/2022 23:08 (9.6 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 12.059 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.235 0.857 1.239 5.075 0.000 kW
0.834 kWh
0.000 kW
5.006 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.228 0.806 1.148 4.725
03 - 202224****** IQ7+M [0] ---- 0.000 0.234 0.861 1.203 5.021
04 - 202232****** IQ7+ [0] ---- 0.000 0.233 0.835 1.192 4.911
05 - 202244****** IQ7+M [0] ---- 0.000 0.231 0.838 1.220 4.945
06 - 202245****** IQ7+M [0] ---- 0.000 0.226 0.809 1.174 4.801
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.286 0.993 1.464 5.799 0.000 kW
0.986 kWh
0.000 kW
4.931 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.287 0.934 1.280 5.383
09 - 202217****** IQ7+ [0] ---- 0.000 0.288 1.008 1.542 6.083
10 - 202244****** IQ7+M [0] ---- 0.000 0.287 0.991 1.519 5.998
11 - 202224****** IQ7+M [0] ---- 0.000 0.287 1.005 1.459 5.812
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.125 0.511 0.497 2.580 0.000 kW
0.530 kWh
0.000 kW
2.122 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.127 0.534 0.575 2.803
14 - 202216****** IQ7+ [0] ---- 0.000 0.129 0.544 0.576 2.818
15 - 202245****** IQ7+M [0] ---- 0.000 0.126 0.533 0.559 2.752
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.17 V Current/Power -2.04 A (-0.108 kW)
Remain Capacity/Energy 521.1 Ah (26.7 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 86.9 % State Of Health 100.0 %
Run Time 10d 15h 26m to empty Report Date 2022-01-23 23:50
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.