Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.165 kW
07/04/2026 00:28 (2229 days) Production Consumption NET Usage
Now 0.226 kW 0.391 kW 0.165 kW
Today 0.113 kWh (0.225 kW) 0.530 kWh (1.056 kW) 0.417 kWh (0.831 kW)
  - This Week 176.065 kWh (29.247 kWh/day) 202.447 kWh (33.629 kWh/day) 26.382 kWh (4.382 kWh/day)
  - This Month 94.464 kWh (31.274 kWh/day) 128.307 kWh (42.478 kWh/day) 33.843 kWh (11.204 kWh/day)
  - This Year 3.704 MWh (20.130 kWh/day) 3.415 MWh (18.558 kWh/day) -0.289 MWh (-1.572 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 186.083 kWh (26.583 kWh/day) 219.339 kWh (31.334 kWh/day) 33.256 kWh (4.751 kWh/day)
Last 30 Days (06/04/2026) 856.235 kWh (28.541 kWh/day) 807.575 kWh (26.919 kWh/day) -48.660 kWh (-1.622 kWh/day)
Last One Year 6.724 MWh (18.421 kWh/day) 7.758 MWh (21.254 kWh/day) 1.034 MWh (2.834 kWh/day)
Lifetime Since PTO 39.270 MWh (17.618 kW/day) 42.926 MWh (19.258 kW/day) 3.656 MWh (1.640 kW/day)
Lifetime Since Install 39.304 MWh 43.506 MWh 4.202 MWh
Voltage/Current 250.5 V / 0.9 A 250.4 V / 1.6 A 250.4 V / 0.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/14/2022 23:05 (9.3 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 12.159 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.189 0.862 0.608 4.444 0.000 kW
0.847 kWh
0.000 kW
5.085 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.183 0.821 0.566 4.180
03 - 202224****** IQ7+M [0] ---- 0.000 0.190 0.863 0.607 4.505
04 - 202232****** IQ7+ [0] ---- 0.000 0.189 0.856 0.591 4.422
05 - 202244****** IQ7+M [0] ---- 0.000 0.188 0.852 0.580 4.248
06 - 202245****** IQ7+M [0] ---- 0.000 0.184 0.831 0.573 4.135
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.245 1.097 0.655 5.370 0.000 kW
1.081 kWh
0.000 kW
5.404 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.243 0.993 0.624 4.986
09 - 202217****** IQ7+ [0] ---- 0.000 0.246 1.120 0.670 5.921
10 - 202244****** IQ7+M [0] ---- 0.000 0.247 1.104 0.652 5.773
11 - 202224****** IQ7+M [0] ---- 0.000 0.245 1.090 0.645 5.487
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.095 0.389 0.412 1.993 0.000 kW
0.418 kWh
0.000 kW
1.670 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.100 0.428 0.429 2.146
14 - 202216****** IQ7+ [0] ---- 0.000 0.101 0.431 0.434 2.120
15 - 202245****** IQ7+M [0] ---- 0.000 0.099 0.422 0.426 1.811
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.32 V Current/Power -1.47 A (-78 W)
Remain Capacity/Energy 386.4 Ah (19.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 64.4 % State Of Health 100.0 %
Run Time 10d 22h 51m to empty Report Date 2022-01-14 23:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.