Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.283 kW
09/13/2025 23:34 (1935 days) Production Consumption NET Usage
Now 0.000 kW 0.283 kW 0.283 kW
Today 22.447 kWh (0.952 kW) 23.791 kWh (1.009 kW) 1.344 kWh (0.057 kW)
  - This Week 148.841 kWh (21.315 kWh/day) 108.455 kWh (15.532 kWh/day) -40.386 kWh (-5.784 kWh/day)
  - This Month 285.769 kWh (22.012 kWh/day) 304.180 kWh (23.430 kWh/day) 18.411 kWh (1.418 kWh/day)
  - This Year 4.793 MWh (18.724 kWh/day) 5.475 MWh (21.388 kWh/day) 0.682 MWh (2.664 kWh/day)
Yesterday 20.907 kWh (0.870 kW) 16.569 kWh (0.690 kW) -4.338 kWh (-0.181 kW)
Last 7 Days 141.741 kWh (20.247 kWh/day) 152.074 kWh (21.723 kWh/day) 10.333 kWh (1.476 kWh/day)
Last 30 Days 686.605 kWh (22.887 kWh/day) 731.787 kWh (24.393 kWh/day) 45.182 kWh (1.506 kWh/day)
Last One Year 6.275 MWh (17.192 kWh/day) 7.087 MWh (19.417 kWh/day) 0.812 MWh (2.225 kWh/day)
Lifetime Since PTO 34.244 MWh (17.688 kW/day) 37.427 MWh (19.332 kW/day) 3.183 MWh (1.644 kW/day)
Lifetime Since Install 34.278 MWh 38.007 MWh 3.729 MWh
Voltage/Current 252.1 V / 0.0 A 252.0 V / 1.1 A 252.1 V / 1.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/25/2021 23:19 (11.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 16.408 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.283 1.149 0.440 10.295 0.000 kW
1.133 kWh
0.000 kW
6.800 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.280 1.120 0.420 10.109
03 - 202224****** IQ7+M [0] ---- 0.000 0.287 1.155 0.438 10.357
04 - 202232****** IQ7+ [0] ---- 0.000 0.285 1.148 0.434 10.351
05 - 202244****** IQ7+M [0] ---- 0.000 0.279 1.110 0.406 9.809
06 - 202245****** IQ7+M [0] ---- 0.000 0.274 1.118 0.422 9.780
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.291 1.181 0.390 10.571 0.000 kW
1.190 kWh
0.000 kW
5.950 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.293 1.181 0.386 9.818
09 - 202217****** IQ7+ [0] ---- 0.000 0.293 1.196 0.394 10.571
10 - 202244****** IQ7+M [0] ---- 0.000 0.299 1.202 0.399 10.790
11 - 202224****** IQ7+M [0] ---- 0.000 0.295 1.191 0.394 10.741
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.200 0.913 0.448 8.141 0.000 kW
0.914 kWh
0.000 kW
3.658 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.201 0.909 0.450 7.927
14 - 202216****** IQ7+ [0] ---- 0.000 0.203 0.925 0.456 8.190
15 - 202245****** IQ7+M [0] ---- 0.000 0.201 0.909 0.448 8.044
wind 16 - 122214****** IQ7PD [5] VC-- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Battery History
Voltage 53.20 V Current/Power -0.90 A (-47 W)
Remain Capacity/Energy 499.8 Ah (25.6 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 84.6 % State Of Health 98.5 %
Run Time 23d 3h 20m to empty Report Date 2021-03-25 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.