Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.630 kW
11/09/2025 09:48 (1992 days) Production Consumption NET Usage
Now 0.877 kW 0.247 kW -0.630 kW
Today 2.015 kWh (0.205 kW) 5.956 kWh (0.606 kW) 3.941 kWh (0.401 kW)
  - This Week 2.015 kWh (4.924 kWh/day) 5.956 kWh (14.553 kWh/day) 3.941 kWh (9.630 kWh/day)
  - This Month 112.048 kWh (13.324 kWh/day) 173.865 kWh (20.675 kWh/day) 61.817 kWh (7.351 kWh/day)
  - This Year 5.690 MWh (18.213 kWh/day) 6.506 MWh (20.826 kWh/day) 0.816 MWh (2.613 kWh/day)
Yesterday 15.394 kWh (0.641 kW) 24.543 kWh (1.022 kW) 9.149 kWh (0.381 kW)
Last 7 Days 93.095 kWh (13.299 kWh/day) 151.721 kWh (21.675 kWh/day) 58.626 kWh (8.375 kWh/day)
Last 30 Days 395.470 kWh (13.182 kWh/day) 463.753 kWh (15.459 kWh/day) 68.283 kWh (2.276 kWh/day)
Last One Year 6.171 MWh (16.908 kWh/day) 7.484 MWh (20.505 kWh/day) 1.313 MWh (3.597 kWh/day)
Lifetime Since PTO 35.141 MWh (17.637 kW/day) 38.459 MWh (19.302 kW/day) 3.318 MWh (1.665 kW/day)
Lifetime Since Install 35.175 MWh 39.039 MWh 3.864 MWh
Voltage/Current 249.3 V / 3.5 A 249.4 V / 1.0 A 249.3 V / -2.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 05/15/2021 23:16 (14.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.231 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.525 1.891 11.189 0.000 kW
1.444 kWh
0.000 kW
8.662 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.443 1.805 10.683
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.462 1.825 10.869
04 - 202232****** IQ7+ [5] VCOP 0.000 0.299 1.500 1.864 11.027
05 - 202244****** IQ7+M [5] VCOP 0.000 0.299 1.278 1.644 9.834
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.454 1.815 10.736
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.294 1.310 1.658 9.872 0.000 kW
1.327 kWh
0.000 kW
6.636 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.315 1.709 9.963
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.333 1.689 10.000
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.341 1.734 10.159
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.336 1.742 10.157
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.280 1.745 1.968 11.756 0.000 kW
1.733 kWh
0.000 kW
6.934 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.281 1.711 1.888 11.459
14 - 202216****** IQ7+ [5] VCOP 0.000 0.282 1.749 1.964 11.749
15 - 202245****** IQ7+M [5] VCOP 0.000 0.277 1.729 1.939 11.592
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.