Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.196 kW
07/04/2026 00:32 (2229 days) Production Consumption NET Usage
Now 0.226 kW 0.422 kW 0.196 kW
Today 0.128 kWh (0.226 kW) 0.556 kWh (0.983 kW) 0.428 kWh (0.757 kW)
  - This Week 176.080 kWh (29.237 kWh/day) 202.473 kWh (33.619 kWh/day) 26.393 kWh (4.382 kWh/day)
  - This Month 94.479 kWh (31.251 kWh/day) 128.333 kWh (42.449 kWh/day) 33.854 kWh (11.198 kWh/day)
  - This Year 3.704 MWh (20.130 kWh/day) 3.415 MWh (18.558 kWh/day) -0.289 MWh (-1.572 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 186.098 kWh (26.585 kWh/day) 219.360 kWh (31.337 kWh/day) 33.262 kWh (4.752 kWh/day)
Last 30 Days (06/04/2026) 856.234 kWh (28.541 kWh/day) 807.579 kWh (26.919 kWh/day) -48.655 kWh (-1.622 kWh/day)
Last One Year 6.724 MWh (18.421 kWh/day) 7.758 MWh (21.254 kWh/day) 1.034 MWh (2.834 kWh/day)
Lifetime Since PTO 39.270 MWh (17.618 kW/day) 42.926 MWh (19.258 kW/day) 3.656 MWh (1.640 kW/day)
Lifetime Since Install 39.304 MWh 43.506 MWh 4.202 MWh
Voltage/Current 250.7 V / 0.9 A 250.6 V / 1.7 A 250.7 V / 0.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/27/2021 22:20 (8.2 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 2.486 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.202 0.179 0.981 4.606 0.000 kW
0.169 kWh
0.000 kW
1.013 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.198 0.163 0.940 4.367
03 - 202224****** IQ7+M [0] ---- 0.000 0.199 0.179 0.986 4.646
04 - 202232****** IQ7+ [0] ---- 0.000 0.213 0.166 0.964 4.537
05 - 202244****** IQ7+M [0] ---- 0.000 0.199 0.166 0.985 4.554
06 - 202245****** IQ7+M [0] ---- 0.000 0.221 0.160 0.953 4.430
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.239 0.177 1.220 5.603 0.000 kW
0.174 kWh
0.000 kW
0.868 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.231 0.176 1.058 5.050
09 - 202217****** IQ7+ [0] ---- 0.000 0.228 0.178 1.284 5.817
10 - 202244****** IQ7+M [0] ---- 0.000 0.227 0.161 1.274 5.684
11 - 202224****** IQ7+M [0] ---- 0.000 0.230 0.177 1.183 5.470
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.093 0.148 0.290 1.922 0.000 kW
0.151 kWh
0.000 kW
0.604 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.095 0.150 0.360 2.172
14 - 202216****** IQ7+ [0] ---- 0.000 0.099 0.154 0.359 2.187
15 - 202245****** IQ7+M [0] ---- 0.000 0.097 0.151 0.350 2.139
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.72 V Current/Power -0.90 A (-47 W)
Remain Capacity/Energy 337.8 Ah (17.3 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 56.3 % State Of Health 100.0 %
Run Time 15d 15h 20m to empty Report Date 2021-12-27 23:52