Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 1.272 kW
07/13/2025 18:17 (1873 days) Production Consumption NET Usage
Now 1.419 kW 2.691 kW 1.272 kW
Today 20.149 kWh (1.100 kW) 23.582 kWh (1.287 kW) 3.433 kWh (0.187 kW)
  - This Week 20.149 kWh (26.389 kWh/day) 23.582 kWh (30.885 kWh/day) 3.433 kWh (4.496 kWh/day)
  - This Month 317.227 kWh (24.854 kWh/day) 520.440 kWh (40.776 kWh/day) 203.213 kWh (15.922 kWh/day)
  - This Year 3.347 MWh (17.273 kWh/day) 3.648 MWh (18.825 kWh/day) 0.301 MWh (1.552 kWh/day)
Yesterday 24.628 kWh (1.026 kW) 41.474 kWh (1.728 kW) 16.846 kWh (0.702 kW)
Last 7 Days 167.369 kWh (23.909 kWh/day) 328.132 kWh (46.874 kWh/day) 160.763 kWh (22.965 kWh/day)
Last 30 Days 650.059 kWh (21.669 kWh/day) 1050.834 kWh (35.029 kWh/day) 400.775 kWh (13.360 kWh/day)
Last One Year 6.270 MWh (17.178 kWh/day) 6.538 MWh (17.912 kWh/day) 0.268 MWh (0.734 kWh/day)
Lifetime Since PTO 32.798 MWh (17.504 kW/day) 35.600 MWh (18.999 kW/day) 2.802 MWh (1.495 kW/day)
Lifetime Since Install 32.832 MWh 36.180 MWh 3.348 MWh
Voltage/Current 247.5 V / 5.7 A 247.3 V / 10.9 A 247.4 V / 5.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/23/2020 21:43 (8.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 10.680 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.193 0.758 0.098 0.296 0.000 kW
0.726 kWh
0.000 kW
4.355 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.173 0.695 0.166 0.354
03 - 202224****** IQ7+M [5] VCOP 0.000 0.166 0.684 0.260 0.475
04 - 202232****** IQ7+ [5] VCOP 0.000 0.164 0.668 0.332 0.547
05 - 202244****** IQ7+M [5] VCOP 0.000 0.174 0.754 0.526 1.008
06 - 202245****** IQ7+M [5] VCOP 0.000 0.184 0.796 0.571 1.138
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.237 0.949 0.703 1.394 0.000 kW
0.943 kWh
0.000 kW
4.717 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.237 0.800 0.658 0.807
09 - 202217****** IQ7+ [5] VCOP 0.000 0.241 1.039 0.718 1.777
10 - 202244****** IQ7+M [5] VCOP 0.000 0.240 1.022 0.718 1.882
11 - 202224****** IQ7+M [5] VCOP 0.000 0.236 0.907 0.696 1.194
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.071 0.376 0.324 1.240 0.000 kW
0.402 kWh
0.000 kW
1.609 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.089 0.415 0.360 1.086
14 - 202216****** IQ7+ [5] VCOP 0.000 0.087 0.415 0.362 1.061
15 - 202245****** IQ7+M [5] VCOP 0.000 0.085 0.402 0.352 1.881
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 51.98 V Current/Power 162.28 A (8.435 kW)
Remain Capacity/Energy 193.5 Ah (9.9 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 32.7 % State Of Health 98.5 %
Run Time 2h 26m to full Report Date 2020-12-22 16:35
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 51.98 V Cell (MIN/MAX) 3.241 V / 3.254 V (0.013 V)
Current/Power -0.50 A (-26 W) Runtime 5d 8h 30m to empty
Remain Capacity/Energy 64.5 Ah (3.3 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 32.7 % State Of Health 98.5 %
Temperature 24.0 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-22 16:35
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.241 V 3.242 V 3.244 V 3.244 V 3.249 V 3.245 V 3.249 V 3.249 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.248 V 3.248 V 3.251 V 3.249 V 3.252 V 3.253 V 3.254 V 3.254 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -