Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.181 kW
07/04/2026 03:24 (2229 days) Production Consumption NET Usage
Now 0.226 kW 0.407 kW 0.181 kW
Today 0.775 kWh (0.226 kW) 3.410 kWh (0.994 kW) 2.635 kWh (0.768 kW)
  - This Week 176.727 kWh (28.774 kWh/day) 205.327 kWh (33.430 kWh/day) 28.600 kWh (4.657 kWh/day)
  - This Month 95.126 kWh (30.271 kWh/day) 131.187 kWh (41.746 kWh/day) 36.061 kWh (11.475 kWh/day)
  - This Year 3.705 MWh (20.120 kWh/day) 3.418 MWh (18.562 kWh/day) -0.287 MWh (-1.559 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 186.745 kWh (26.678 kWh/day) 221.754 kWh (31.679 kWh/day) 35.009 kWh (5.001 kWh/day)
Last 30 Days (06/04/2026) 855.970 kWh (28.532 kWh/day) 808.996 kWh (26.967 kWh/day) -46.974 kWh (-1.566 kWh/day)
Last One Year 6.724 MWh (18.423 kWh/day) 7.760 MWh (21.259 kWh/day) 1.035 MWh (2.837 kWh/day)
Lifetime Since PTO 39.271 MWh (17.617 kW/day) 42.929 MWh (19.258 kW/day) 3.658 MWh (1.641 kW/day)
Lifetime Since Install 39.305 MWh 43.509 MWh 4.204 MWh
Voltage/Current 250.4 V / 0.9 A 250.3 V / 1.6 A 250.4 V / 0.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/10/2021 21:56 (9.7 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.032 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.223 1.075 1.052 7.697 0.000 kW
1.054 kWh
0.000 kW
6.321 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.216 1.009 0.957 7.147
03 - 202224****** IQ7+M [0] ---- 0.000 0.220 1.080 1.043 7.594
04 - 202232****** IQ7+ [0] ---- 0.000 0.218 1.038 0.941 7.314
05 - 202244****** IQ7+M [0] ---- 0.000 0.219 1.072 1.038 7.546
06 - 202245****** IQ7+M [0] ---- 0.000 0.216 1.047 1.032 7.343
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.275 1.256 1.214 8.701 0.000 kW
1.302 kWh
0.000 kW
6.511 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.275 1.121 1.071 7.590
09 - 202217****** IQ7+ [0] ---- 0.000 0.276 1.427 1.364 9.561
10 - 202244****** IQ7+M [0] ---- 0.000 0.271 1.395 1.323 9.354
11 - 202224****** IQ7+M [0] ---- 0.000 0.273 1.311 1.264 8.996
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.136 0.500 0.519 4.278 0.000 kW
0.550 kWh
0.000 kW
2.200 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.134 0.568 0.563 4.565
14 - 202216****** IQ7+ [0] ---- 0.000 0.140 0.572 0.543 4.581
15 - 202245****** IQ7+M [0] ---- 0.000 0.137 0.560 0.545 4.505
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 52.98 V Current/Power -6.90 A (-0.366 kW)
Remain Capacity/Energy 366.9 Ah (18.8 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 61.2 % State Of Health 100.0 %
Run Time 2d 5h 10m to empty Report Date 2021-11-10 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.