Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.089 kW
05/16/2026 10:12 (2180 days) Production Consumption NET Usage
Now 2.936 kW -0.153 kW -3.089 kW
Today 4.670 kWh (0.457 kW) 1.074 kWh (0.105 kW) -3.596 kWh (-0.352 kW)
  - This Week 155.493 kWh (24.198 kWh/day) 76.721 kWh (11.940 kWh/day) -78.772 kWh (-12.259 kWh/day)
  - This Month 373.568 kWh (24.218 kWh/day) 193.858 kWh (12.568 kWh/day) -179.710 kWh (-11.650 kWh/day)
  - This Year 2.327 MWh (17.180 kWh/day) 2.254 MWh (16.641 kWh/day) -0.073 MWh (-0.539 kWh/day)
Yesterday 21.295 kWh (0.887 kW) 9.495 kWh (0.396 kW) -11.800 kWh (-0.492 kW)
Last 7 Days 162.561 kWh (23.223 kWh/day) 87.271 kWh (12.467 kWh/day) -75.290 kWh (-10.756 kWh/day)
Last 30 Days (04/16/2026) 683.265 kWh (22.776 kWh/day) 390.846 kWh (13.028 kWh/day) -292.419 kWh (-9.747 kWh/day)
Last One Year 6.340 MWh (17.370 kWh/day) 7.785 MWh (21.329 kWh/day) 1.445 MWh (3.960 kWh/day)
Lifetime Since PTO 37.892 MWh (17.378 kW/day) 41.764 MWh (19.154 kW/day) 3.872 MWh (1.776 kW/day)
Lifetime Since Install 37.926 MWh 42.344 MWh 4.418 MWh
Voltage/Current 250.5 V / 11.7 A 250.5 V / -0.6 A 250.5 V / -12.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/20/2021 23:04 (11.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 20.138 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.300 1.412 1.856 8.751 0.000 kW
1.375 kWh
0.000 kW
8.252 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.340 1.825 8.504
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.425 1.873 8.771
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.422 1.852 8.699
05 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.340 1.785 8.407
06 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.313 1.766 8.363
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.301 1.415 1.965 8.861 0.000 kW
1.398 kWh
0.000 kW
6.990 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.290 1.838 8.374
09 - 202217****** IQ7+ [5] VCOP 0.000 0.300 1.426 1.950 8.875
10 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.430 1.955 8.900
11 - 202224****** IQ7+M [5] VCOP 0.000 0.300 1.430 1.968 8.899
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.229 1.228 1.446 7.269 0.000 kW
1.224 kWh
0.000 kW
4.896 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.231 1.208 1.396 7.150
14 - 202216****** IQ7+ [5] VCOP 0.000 0.231 1.240 1.457 7.339
15 - 202245****** IQ7+M [5] VCOP 0.000 0.230 1.220 1.429 7.204
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.