Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.986 kW
07/14/2025 11:22 (1874 days) Production Consumption NET Usage
Now 2.384 kW 0.398 kW -1.986 kW
Today 6.026 kWh (0.528 kW) 9.062 kWh (0.794 kW) 3.036 kWh (0.266 kW)
  - This Week 26.873 kWh (18.215 kWh/day) 42.985 kWh (29.136 kWh/day) 16.112 kWh (10.921 kWh/day)
  - This Month 323.951 kWh (24.041 kWh/day) 539.843 kWh (40.062 kWh/day) 215.892 kWh (16.021 kWh/day)
  - This Year 3.354 MWh (17.245 kWh/day) 3.667 MWh (18.856 kWh/day) 0.313 MWh (1.612 kWh/day)
Yesterday 20.847 kWh (0.869 kW) 33.923 kWh (1.414 kW) 13.076 kWh (0.545 kW)
Last 7 Days 156.584 kWh (22.371 kWh/day) 312.899 kWh (44.705 kWh/day) 156.315 kWh (22.333 kWh/day)
Last 30 Days 646.442 kWh (21.549 kWh/day) 1060.961 kWh (35.367 kWh/day) 414.519 kWh (13.818 kWh/day)
Last One Year 6.268 MWh (17.171 kWh/day) 6.542 MWh (17.922 kWh/day) 0.274 MWh (0.751 kWh/day)
Lifetime Since PTO 32.805 MWh (17.501 kW/day) 35.619 MWh (19.002 kW/day) 2.815 MWh (1.501 kW/day)
Lifetime Since Install 32.838 MWh 36.199 MWh 3.361 MWh
Voltage/Current 248.0 V / 9.6 A 247.9 V / 1.6 A 247.9 V / -8.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/17/2020 21:53 (9.3 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 5.735 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.147 0.397 1.152 4.074 0.000 kW
0.392 kWh
0.000 kW
2.350 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.146 0.392 1.133 4.086
03 - 202224****** IQ7+M [5] VCOP 0.000 0.151 0.399 1.126 4.107
04 - 202232****** IQ7+ [5] VCOP 0.000 0.145 0.388 1.082 3.983
05 - 202244****** IQ7+M [5] VCOP 0.000 0.147 0.387 1.165 4.008
06 - 202245****** IQ7+M [5] VCOP 0.000 0.146 0.389 1.136 3.860
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.168 0.388 1.351 4.587 0.000 kW
0.391 kWh
0.000 kW
1.957 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.168 0.385 1.196 4.055
09 - 202217****** IQ7+ [5] VCOP 0.000 0.172 0.396 1.495 5.013
10 - 202244****** IQ7+M [5] VCOP 0.000 0.169 0.398 1.475 4.970
11 - 202224****** IQ7+M [5] VCOP 0.000 0.168 0.390 1.379 4.694
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.093 0.355 0.501 2.356 0.000 kW
0.357 kWh
0.000 kW
1.429 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.095 0.357 0.572 2.535
14 - 202216****** IQ7+ [5] VCOP 0.000 0.095 0.363 0.564 2.459
15 - 202245****** IQ7+M [5] VCOP 0.000 0.093 0.354 0.548 2.455
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 52.48 V Current/Power 163.88 A (8.600 kW)
Remain Capacity/Energy 352.8 Ah (18.1 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 59.7 % State Of Health 98.5 %
Run Time 1h 27m to full Report Date 2020-11-17 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.48 V Cell (MIN/MAX) 3.275 V / 3.284 V (0.009 V)
Current/Power -0.58 A (-30 W) Runtime 8d 9h 22m to empty
Remain Capacity/Energy 117.6 Ah (6.0 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 59.7 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-11-17 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.275 V 3.275 V 3.276 V 3.276 V 3.278 V 3.278 V 3.279 V 3.279 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.280 V 3.280 V 3.281 V 3.281 V 3.283 V 3.283 V 3.283 V 3.284 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -