Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 2.270 kW
07/14/2025 11:18 (1874 days) Production Consumption NET Usage
Now 2.708 kW 0.438 kW -2.270 kW
Today 5.790 kWh (0.510 kW) 9.032 kWh (0.796 kW) 3.242 kWh (0.286 kW)
  - This Week 26.637 kWh (18.092 kWh/day) 42.955 kWh (29.175 kWh/day) 16.318 kWh (11.083 kWh/day)
  - This Month 323.715 kWh (24.028 kWh/day) 539.813 kWh (40.069 kWh/day) 216.098 kWh (16.040 kWh/day)
  - This Year 3.353 MWh (17.244 kWh/day) 3.667 MWh (18.856 kWh/day) 0.314 MWh (1.613 kWh/day)
Yesterday 20.847 kWh (0.869 kW) 33.923 kWh (1.414 kW) 13.076 kWh (0.545 kW)
Last 7 Days 156.584 kWh (22.371 kWh/day) 312.899 kWh (44.705 kWh/day) 156.315 kWh (22.333 kWh/day)
Last 30 Days 646.442 kWh (21.549 kWh/day) 1060.961 kWh (35.367 kWh/day) 414.519 kWh (13.818 kWh/day)
Last One Year 6.268 MWh (17.171 kWh/day) 6.542 MWh (17.922 kWh/day) 0.274 MWh (0.751 kWh/day)
Lifetime Since PTO 32.804 MWh (17.501 kW/day) 35.619 MWh (19.002 kW/day) 2.815 MWh (1.502 kW/day)
Lifetime Since Install 32.838 MWh 36.199 MWh 3.361 MWh
Voltage/Current 248.1 V / 10.9 A 248.1 V / 1.8 A 248.1 V / -9.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/08/2020 21:56 (9.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.543 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.210 1.092 1.102 6.838 0.000 kW
1.094 kWh
0.000 kW
6.563 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.207 1.081 1.083 6.690
03 - 202224****** IQ7+M [5] VCOP 0.000 0.211 1.100 1.102 6.764
04 - 202232****** IQ7+ [5] VCOP 0.000 0.210 1.086 1.091 6.712
05 - 202244****** IQ7+M [5] VCOP 0.000 0.210 1.103 1.108 6.836
06 - 202245****** IQ7+M [5] VCOP 0.000 0.207 1.100 1.105 6.861
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.257 1.268 1.288 8.131 0.000 kW
1.315 kWh
0.000 kW
6.575 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.256 1.130 1.135 7.437
09 - 202217****** IQ7+ [5] VCOP 0.000 0.255 1.440 1.460 8.758
10 - 202244****** IQ7+M [5] VCOP 0.000 0.256 1.418 1.433 8.720
11 - 202224****** IQ7+M [5] VCOP 0.000 0.254 1.321 1.349 8.388
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.118 0.562 0.573 3.775 0.000 kW
0.601 kWh
0.000 kW
2.405 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.118 0.621 0.628 4.081
14 - 202216****** IQ7+ [5] VCOP 0.000 0.118 0.619 0.627 4.091
15 - 202245****** IQ7+M [5] VCOP 0.000 0.115 0.603 0.611 4.009
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 57.03 V Current/Power 178.16 A (10.161 kW)
Remain Capacity/Energy 589.8 Ah (30.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.8 % State Of Health 98.5 %
Run Time - to full Report Date 2020-11-08 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 57.03 V Cell (MIN/MAX) 3.551 V / 3.570 V (0.019 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 196.6 Ah (10.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 99.8 % State Of Health 98.5 %
Temperature 23.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-11-08 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.561 V 3.558 V 3.551 V 3.565 V 3.564 V 3.563 V 3.567 V 3.567 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.561 V 3.563 V 3.566 V 3.565 V 3.569 V 3.570 V 3.566 V 3.568 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -