Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.513 kW
07/14/2025 11:55 (1874 days) Production Consumption NET Usage
Now 1.878 kW 0.365 kW -1.513 kW
Today 7.119 kWh (0.595 kW) 9.478 kWh (0.792 kW) 2.359 kWh (0.197 kW)
  - This Week 27.966 kWh (18.671 kWh/day) 43.401 kWh (28.976 kWh/day) 15.435 kWh (10.305 kWh/day)
  - This Month 325.044 kWh (24.081 kWh/day) 540.259 kWh (40.026 kWh/day) 215.215 kWh (15.945 kWh/day)
  - This Year 3.355 MWh (17.248 kWh/day) 3.667 MWh (18.856 kWh/day) 0.313 MWh (1.608 kWh/day)
Yesterday 20.847 kWh (0.869 kW) 33.923 kWh (1.414 kW) 13.076 kWh (0.545 kW)
Last 7 Days 156.584 kWh (22.371 kWh/day) 312.899 kWh (44.705 kWh/day) 156.315 kWh (22.333 kWh/day)
Last 30 Days 646.442 kWh (21.549 kWh/day) 1060.961 kWh (35.367 kWh/day) 414.519 kWh (13.818 kWh/day)
Last One Year 6.268 MWh (17.171 kWh/day) 6.542 MWh (17.922 kWh/day) 0.274 MWh (0.751 kWh/day)
Lifetime Since PTO 32.806 MWh (17.501 kW/day) 35.619 MWh (19.002 kW/day) 2.814 MWh (1.501 kW/day)
Lifetime Since Install 32.840 MWh 36.199 MWh 3.360 MWh
Voltage/Current 248.1 V / 7.6 A 247.9 V / 1.5 A 248.0 V / -6.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/28/2020 23:24 (9.5 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 3.345 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.117 0.233 0.572 3.062 0.000 kW
0.231 kWh
0.000 kW
1.385 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.116 0.230 0.565 3.018
03 - 202224****** IQ7+M [5] VCOP 0.000 0.118 0.235 0.577 3.083
04 - 202232****** IQ7+ [5] VCOP 0.000 0.116 0.231 0.567 3.033
05 - 202244****** IQ7+M [5] VCOP 0.000 0.115 0.227 0.563 3.004
06 - 202245****** IQ7+M [5] VCOP 0.000 0.115 0.229 0.566 3.012
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.113 0.212 0.592 3.046 0.000 kW
0.214 kWh
0.000 kW
1.069 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.114 0.212 0.591 2.978
09 - 202217****** IQ7+ [5] VCOP 0.000 0.116 0.214 0.598 3.116
10 - 202244****** IQ7+M [5] VCOP 0.000 0.116 0.216 0.600 3.132
11 - 202224****** IQ7+M [5] VCOP 0.000 0.115 0.214 0.593 3.087
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.102 0.220 0.438 2.533 0.000 kW
0.223 kWh
0.000 kW
0.891 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.103 0.222 0.445 2.566
14 - 202216****** IQ7+ [5] VCOP 0.000 0.104 0.226 0.450 2.603
15 - 202245****** IQ7+M [5] VCOP 0.000 0.103 0.222 0.441 2.556
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 57.01 V Current/Power 178.04 A (10.150 kW)
Remain Capacity/Energy 591.0 Ah (30.3 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 100.0 % State Of Health 98.5 %
Run Time - to full Report Date 2020-10-28 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 57.01 V Cell (MIN/MAX) 3.552 V / 3.568 V (0.016 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 197.0 Ah (10.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 100.0 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 26
MOSFET CFET = ON, DFET = ON Reported 2020-10-28 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.559 V 3.561 V 3.560 V 3.563 V 3.552 V 3.554 V 3.568 V 3.563 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.558 V 3.563 V 3.567 V 3.567 V 3.566 V 3.568 V 3.567 V 3.567 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -