Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.353 kW
07/14/2025 17:15 (1874 days) Production Consumption NET Usage
Now 0.042 kW 2.395 kW 2.353 kW
Today 18.315 kWh (1.059 kW) 19.113 kWh (1.105 kW) 0.798 kWh (0.046 kW)
  - This Week 39.162 kWh (22.764 kWh/day) 53.036 kWh (30.828 kWh/day) 13.874 kWh (8.065 kWh/day)
  - This Month 336.240 kWh (24.507 kWh/day) 549.894 kWh (40.079 kWh/day) 213.654 kWh (15.572 kWh/day)
  - This Year 3.366 MWh (17.286 kWh/day) 3.677 MWh (18.884 kWh/day) 0.311 MWh (1.598 kWh/day)
Yesterday 20.847 kWh (0.869 kW) 33.923 kWh (1.414 kW) 13.076 kWh (0.545 kW)
Last 7 Days 156.584 kWh (22.371 kWh/day) 312.899 kWh (44.705 kWh/day) 156.315 kWh (22.333 kWh/day)
Last 30 Days 646.442 kWh (21.549 kWh/day) 1060.961 kWh (35.367 kWh/day) 414.519 kWh (13.818 kWh/day)
Last One Year 6.268 MWh (17.171 kWh/day) 6.542 MWh (17.922 kWh/day) 0.274 MWh (0.751 kWh/day)
Lifetime Since PTO 32.817 MWh (17.505 kW/day) 35.629 MWh (19.005 kW/day) 2.812 MWh (1.500 kW/day)
Lifetime Since Install 32.851 MWh 36.209 MWh 3.358 MWh
Voltage/Current 248.9 V / 0.2 A 249.0 V / 9.6 A 249.0 V / 9.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 10/17/2020 22:26 (10.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 22.958 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.260 1.650 0.099 5.302 0.000 kW
1.624 kWh
0.000 kW
9.745 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.255 1.609 0.096 5.205
03 - 202224****** IQ7+M [5] VCOP 0.000 0.257 1.624 0.099 5.265
04 - 202232****** IQ7+ [5] VCOP 0.000 0.255 1.608 0.097 5.197
05 - 202244****** IQ7+M [5] VCOP 0.000 0.257 1.626 0.095 5.196
06 - 202245****** IQ7+M [5] VCOP 0.000 0.254 1.629 0.097 5.206
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.844 0.087 5.501 0.000 kW
1.856 kWh
0.000 kW
9.280 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.704 0.087 5.156
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.906 0.088 5.672
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.928 0.088 5.748
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.897 0.087 5.654
back 12 - 202211****** IQ7+ [5] VC-- 0.000 0.169 0.957 0.095 3.845 0.000 kW
0.983 kWh
0.000 kW
3.933 kWh
13 - 202223****** IQ7+ [5] VC-- 0.000 0.169 0.991 0.097 3.855
14 - 202216****** IQ7+ [5] VCOP 0.000 0.168 1.002 0.098 3.942
15 - 202245****** IQ7+M [5] VCOP 0.000 0.165 0.982 0.096 3.877
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 53.13 V Current/Power 165.92 A (8.815 kW)
Remain Capacity/Energy 414.6 Ah (21.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 70.2 % State Of Health 98.5 %
Run Time 1h 3m to full Report Date 2020-10-17 14:47
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.13 V Cell (MIN/MAX) 3.315 V / 3.325 V (0.010 V)
Current/Power -0.45 A (-23 W) Runtime 12d 19h 6m to empty
Remain Capacity/Energy 138.2 Ah (7.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 70.2 % State Of Health 98.5 %
Temperature 22.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-10-17 14:47
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.315 V 3.317 V 3.317 V 3.317 V 3.319 V 3.318 V 3.319 V 3.319 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.322 V 3.321 V 3.322 V 3.323 V 3.324 V 3.324 V 3.324 V 3.325 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -