Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.275 kW
09/14/2025 07:15 (1936 days) Production Consumption NET Usage
Now 0.136 kW 0.411 kW 0.275 kW
Today 0.032 kWh (0.004 kW) 2.695 kWh (0.370 kW) 2.663 kWh (0.366 kW)
  - This Week 0.032 kWh (0.106 kWh/day) 2.695 kWh (8.892 kWh/day) 2.663 kWh (8.786 kWh/day)
  - This Month 285.801 kWh (21.485 kWh/day) 307.252 kWh (23.098 kWh/day) 21.451 kWh (1.613 kWh/day)
  - This Year 4.793 MWh (18.701 kWh/day) 5.478 MWh (21.373 kWh/day) 0.685 MWh (2.672 kWh/day)
Yesterday 22.447 kWh (0.936 kW) 24.168 kWh (1.008 kW) 1.721 kWh (0.072 kW)
Last 7 Days 148.841 kWh (21.265 kWh/day) 108.832 kWh (15.549 kWh/day) -40.009 kWh (-5.716 kWh/day)
Last 30 Days 687.521 kWh (22.918 kWh/day) 722.998 kWh (24.100 kWh/day) 35.477 kWh (1.183 kWh/day)
Last One Year 6.273 MWh (17.187 kWh/day) 7.101 MWh (19.456 kWh/day) 0.828 MWh (2.269 kWh/day)
Lifetime Since PTO 34.244 MWh (17.685 kW/day) 37.430 MWh (19.331 kW/day) 3.186 MWh (1.645 kW/day)
Lifetime Since Install 34.278 MWh 38.010 MWh 3.732 MWh
Voltage/Current 255.3 V / 0.5 A 255.1 V / 1.6 A 255.2 V / 1.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/14/2020 21:47 (16.4 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 1.295 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.028 0.097 0.660 3.731 0.000 kW
0.095 kWh
0.000 kW
0.568 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.028 0.093 0.642 3.619
03 - 202224****** IQ7+M [5] VCOP 0.000 0.028 0.098 0.645 3.597
04 - 202232****** IQ7+ [5] VCOP 0.000 0.027 0.094 0.632 3.440
05 - 202244****** IQ7+M [5] VCOP 0.000 0.027 0.094 0.708 3.871
06 - 202245****** IQ7+M [5] VCOP 0.000 0.027 0.093 0.713 3.900
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.025 0.085 0.810 4.582 0.000 kW
0.068 kWh
0.000 kW
0.342 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.000 0.000 0.000 1.424
09 - 202217****** IQ7+ [5] VCOP 0.000 0.025 0.085 0.880 4.912
10 - 202244****** IQ7+M [5] VCOP 0.000 0.025 0.086 0.871 4.866
11 - 202224****** IQ7+M [5] VCOP 0.000 0.025 0.085 0.783 4.545
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.028 0.095 0.369 2.017 0.000 kW
0.096 kWh
0.000 kW
0.385 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.028 0.096 0.387 2.177
14 - 202216****** IQ7+ [5] VCOP 0.000 0.029 0.098 0.387 2.183
15 - 202245****** IQ7+M [5] VCOP 0.000 0.028 0.096 0.375 2.118
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.18 V Current/Power 166.08 A (8.832 kW)
Remain Capacity/Energy 497.1 Ah (25.5 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 84.1 % State Of Health 98.5 %
Run Time 33m to full Report Date 2020-12-14 08:57
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.18 V Cell (MIN/MAX) 3.318 V / 3.328 V (0.010 V)
Current/Power -0.50 A (-26 W) Runtime 13d 16h 46m to empty
Remain Capacity/Energy 165.7 Ah (8.5 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 84.1 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-14 08:57
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.318 V 3.319 V 3.320 V 3.320 V 3.321 V 3.322 V 3.322 V 3.323 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.324 V 3.324 V 3.325 V 3.325 V 3.326 V 3.327 V 3.327 V 3.328 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -