Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.076 kW
09/14/2025 07:43 (1936 days) Production Consumption NET Usage
Now 0.336 kW 0.260 kW -0.076 kW
Today 0.155 kWh (0.020 kW) 3.193 kWh (0.412 kW) 3.038 kWh (0.392 kW)
  - This Week 0.155 kWh (0.480 kWh/day) 3.193 kWh (9.895 kWh/day) 3.038 kWh (9.415 kWh/day)
  - This Month 285.924 kWh (21.463 kWh/day) 307.750 kWh (23.101 kWh/day) 21.826 kWh (1.638 kWh/day)
  - This Year 4.793 MWh (18.700 kWh/day) 5.478 MWh (21.373 kWh/day) 0.685 MWh (2.673 kWh/day)
Yesterday 22.447 kWh (0.936 kW) 24.168 kWh (1.008 kW) 1.721 kWh (0.072 kW)
Last 7 Days 148.841 kWh (21.265 kWh/day) 108.832 kWh (15.549 kWh/day) -40.009 kWh (-5.716 kWh/day)
Last 30 Days 687.521 kWh (22.918 kWh/day) 722.998 kWh (24.100 kWh/day) 35.477 kWh (1.183 kWh/day)
Last One Year 6.273 MWh (17.187 kWh/day) 7.101 MWh (19.456 kWh/day) 0.828 MWh (2.269 kWh/day)
Lifetime Since PTO 34.244 MWh (17.685 kW/day) 37.430 MWh (19.331 kW/day) 3.186 MWh (1.646 kW/day)
Lifetime Since Install 34.278 MWh 38.010 MWh 3.732 MWh
Voltage/Current 254.2 V / 1.3 A 254.2 V / 1.0 A 254.2 V / -0.3 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/08/2020 21:45 (8.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 5.502 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VC-- 0.000 0.197 0.369 0.776 4.018 0.000 kW
0.371 kWh
0.000 kW
2.223 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.196 0.364 0.748 3.902
03 - 202224****** IQ7+M [5] VCOP 0.000 0.197 0.377 0.727 3.849
04 - 202232****** IQ7+ [5] VCOP 0.000 0.194 0.373 0.690 3.652
05 - 202244****** IQ7+M [5] VCOP 0.000 0.198 0.376 0.796 4.177
06 - 202245****** IQ7+M [5] VC-- 0.000 0.197 0.364 0.794 4.167
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.275 0.434 0.999 4.930 0.000 kW
0.449 kWh
0.000 kW
2.244 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.274 0.433 0.940 4.434
09 - 202217****** IQ7+ [5] VCOP 0.000 0.275 0.462 1.050 5.255
10 - 202244****** IQ7+M [5] VCOP 0.000 0.277 0.462 1.050 5.230
11 - 202224****** IQ7+M [5] VCOP 0.000 0.272 0.454 1.014 4.903
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.072 0.256 0.347 2.078 0.000 kW
0.259 kWh
0.000 kW
1.034 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.072 0.259 0.387 2.276
14 - 202216****** IQ7+ [5] VCOP 0.000 0.073 0.262 0.386 2.271
15 - 202245****** IQ7+M [5] VCOP 0.000 0.071 0.257 0.377 2.217
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.70 V Current/Power 164.31 A (8.659 kW)
Remain Capacity/Energy 371.7 Ah (19.0 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 62.9 % State Of Health 98.5 %
Run Time 1h 20m to full Report Date 2020-12-08 23:42
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 52.70 V Cell (MIN/MAX) 3.284 V / 3.307 V (0.023 V)
Current/Power -0.57 A (-30 W) Runtime 9d 0h 36m to empty
Remain Capacity/Energy 123.9 Ah (6.3 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 62.9 % State Of Health 98.5 %
Temperature 22.5 °C Cycle 28
MOSFET CFET = ON, DFET = ON Reported 2020-12-08 23:42
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.285 V 3.284 V 3.285 V 3.285 V 3.291 V 3.286 V 3.289 V 3.287 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.298 V 3.289 V 3.303 V 3.291 V 3.303 V 3.305 V 3.305 V 3.307 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -