Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.723 kW
05/16/2026 11:22 (2180 days) Production Consumption NET Usage
Now 3.667 kW -0.056 kW -3.723 kW
Today 8.609 kWh (0.756 kW) 1.246 kWh (0.109 kW) -7.363 kWh (-0.646 kW)
  - This Week 159.432 kWh (24.623 kWh/day) 76.893 kWh (11.876 kWh/day) -82.539 kWh (-12.748 kWh/day)
  - This Month 377.507 kWh (24.396 kWh/day) 194.030 kWh (12.539 kWh/day) -183.477 kWh (-11.857 kWh/day)
  - This Year 2.331 MWh (17.203 kWh/day) 2.254 MWh (16.636 kWh/day) -0.077 MWh (-0.567 kWh/day)
Yesterday 21.295 kWh (0.887 kW) 9.495 kWh (0.396 kW) -11.800 kWh (-0.492 kW)
Last 7 Days 164.709 kWh (23.530 kWh/day) 87.072 kWh (12.439 kWh/day) -77.637 kWh (-11.091 kWh/day)
Last 30 Days (04/16/2026) 683.803 kWh (22.793 kWh/day) 389.779 kWh (12.993 kWh/day) -294.024 kWh (-9.801 kWh/day)
Last One Year 6.342 MWh (17.375 kWh/day) 7.785 MWh (21.329 kWh/day) 1.443 MWh (3.954 kWh/day)
Lifetime Since PTO 37.896 MWh (17.380 kW/day) 41.765 MWh (19.154 kW/day) 3.868 MWh (1.774 kW/day)
Lifetime Since Install 37.930 MWh 42.344 MWh 4.414 MWh
Voltage/Current 250.0 V / 14.7 A 249.9 V / -0.2 A 250.0 V / -14.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/31/2021 21:17 (14.0 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 31.664 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.299 2.231 2.177 11.191 0.000 kW
2.138 kWh
0.000 kW
12.826 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.298 2.128 2.085 10.756
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 2.158 2.114 10.962
04 - 202232****** IQ7+ [5] VCOP 0.000 0.299 2.192 2.138 11.033
05 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.985 1.970 10.194
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 2.133 2.098 10.795
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.298 2.039 1.967 10.192 0.000 kW
2.061 kWh
0.000 kW
10.307 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.300 2.063 2.046 10.323
09 - 202217****** IQ7+ [5] VCOP 0.000 0.298 2.032 2.001 10.299
10 - 202244****** IQ7+M [5] VCOP 0.000 0.299 2.078 2.063 10.464
11 - 202224****** IQ7+M [5] VCOP 0.000 0.298 2.095 2.079 10.468
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.266 2.175 2.051 10.865 0.000 kW
2.133 kWh
0.000 kW
8.531 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.268 2.075 1.949 10.549
14 - 202216****** IQ7+ [5] VCOP 0.000 0.266 2.156 2.044 10.903
15 - 202245****** IQ7+M [5] VCOP 0.000 0.260 2.125 2.009 10.767
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 525.3 Ah (26.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.6 % State Of Health 100.0 %
Run Time 14d 14h 11m to empty Report Date 2021-07-31 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.