Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.091 kW
07/14/2025 18:22 (1874 days) Production Consumption NET Usage
Now 0.000 kW 2.091 kW 2.091 kW
Today 18.325 kWh (0.995 kW) 20.689 kWh (1.123 kW) 2.364 kWh (0.128 kW)
  - This Week 39.172 kWh (22.170 kWh/day) 54.612 kWh (30.908 kWh/day) 15.440 kWh (8.738 kWh/day)
  - This Month 336.250 kWh (24.425 kWh/day) 551.470 kWh (40.058 kWh/day) 215.220 kWh (15.633 kWh/day)
  - This Year 3.366 MWh (17.282 kWh/day) 3.679 MWh (18.888 kWh/day) 0.313 MWh (1.606 kWh/day)
Yesterday 20.847 kWh (0.869 kW) 33.923 kWh (1.414 kW) 13.076 kWh (0.545 kW)
Last 7 Days 156.584 kWh (22.371 kWh/day) 312.899 kWh (44.705 kWh/day) 156.315 kWh (22.333 kWh/day)
Last 30 Days 646.442 kWh (21.549 kWh/day) 1060.961 kWh (35.367 kWh/day) 414.519 kWh (13.818 kWh/day)
Last One Year 6.268 MWh (17.171 kWh/day) 6.542 MWh (17.922 kWh/day) 0.274 MWh (0.751 kWh/day)
Lifetime Since PTO 32.817 MWh (17.505 kW/day) 35.631 MWh (19.005 kW/day) 2.814 MWh (1.501 kW/day)
Lifetime Since Install 32.851 MWh 36.211 MWh 3.360 MWh
Voltage/Current 249.4 V / 0.0 A 249.3 V / 8.4 A 249.3 V / 8.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/14/2020 23:14 (12.1 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 20.903 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.274 1.464 0.989 9.270 0.000 kW
1.451 kWh
0.000 kW
8.709 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.270 1.447 0.981 9.203
03 - 202224****** IQ7+M [0] ---- 0.000 0.274 1.467 1.005 9.396
04 - 202232****** IQ7+ [0] ---- 0.000 0.270 1.452 0.993 9.348
05 - 202244****** IQ7+M [0] ---- 0.000 0.271 1.436 0.927 8.959
06 - 202245****** IQ7+M [0] ---- 0.000 0.268 1.442 0.935 8.971
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.294 1.474 0.934 9.316 0.000 kW
1.474 kWh
0.000 kW
7.368 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.295 1.429 0.871 9.057
09 - 202217****** IQ7+ [0] ---- 0.000 0.293 1.485 0.937 9.277
10 - 202244****** IQ7+M [0] ---- 0.000 0.293 1.496 0.954 9.522
11 - 202224****** IQ7+M [0] ---- 0.000 0.296 1.484 0.943 9.452
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.207 1.212 0.966 8.069 0.000 kW
1.207 kWh
0.000 kW
4.826 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.207 1.203 0.961 7.955
14 - 202216****** IQ7+ [0] ---- 0.000 0.207 1.217 0.976 8.149
15 - 202245****** IQ7+M [0] ---- 0.000 0.203 1.195 0.964 8.036
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 57.62 V Current/Power 179.81 A (10.360 kW)
Remain Capacity/Energy 579.9 Ah (29.7 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 98.1 % State Of Health 98.5 %
Run Time 3m to full Report Date 2020-09-14 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.