Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.183 kW
07/04/2026 06:36 (2229 days) Production Consumption NET Usage
Now 0.541 kW 0.724 kW 0.183 kW
Today 1.667 kWh (0.251 kW) 5.911 kWh (0.890 kW) 4.244 kWh (0.639 kW)
  - This Week 177.619 kWh (28.302 kWh/day) 207.828 kWh (33.116 kWh/day) 30.209 kWh (4.814 kWh/day)
  - This Month 96.018 kWh (29.306 kWh/day) 133.688 kWh (40.803 kWh/day) 37.670 kWh (11.497 kWh/day)
  - This Year 3.706 MWh (20.110 kWh/day) 3.420 MWh (18.562 kWh/day) -0.285 MWh (-1.549 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 187.562 kWh (26.795 kWh/day) 224.104 kWh (32.015 kWh/day) 36.542 kWh (5.220 kWh/day)
Last 30 Days (06/04/2026) 855.704 kWh (28.523 kWh/day) 810.070 kWh (27.002 kWh/day) -45.634 kWh (-1.521 kWh/day)
Last One Year 6.725 MWh (18.425 kWh/day) 7.761 MWh (21.262 kWh/day) 1.036 MWh (2.837 kWh/day)
Lifetime Since PTO 39.272 MWh (17.616 kW/day) 42.931 MWh (19.258 kW/day) 3.660 MWh (1.642 kW/day)
Lifetime Since Install 39.305 MWh 43.511 MWh 4.206 MWh
Voltage/Current 248.3 V / 2.2 A 248.2 V / 2.9 A 248.3 V / 0.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/28/2021 23:25 (12.4 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 9.700 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.196 0.675 1.372 9.154 0.000 kW
0.663 kWh
0.000 kW
3.976 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.199 0.654 1.310 7.671
03 - 202224****** IQ7+M [5] VCOP 0.000 0.194 0.676 1.376 9.139
04 - 202232****** IQ7+ [5] VCOP 0.000 0.196 0.669 1.391 9.203
05 - 202244****** IQ7+M [5] VCOP 0.000 0.196 0.645 1.252 8.558
06 - 202245****** IQ7+M [5] VCOP 0.000 0.195 0.656 1.287 8.225
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.196 0.610 1.276 8.775 0.000 kW
0.612 kWh
0.000 kW
3.059 kWh
08 - 202245****** IQ7+M [5] VC-- 0.000 0.189 0.603 1.218 8.702
09 - 202217****** IQ7+ [5] VCOP 0.000 0.204 0.616 1.262 8.736
10 - 202244****** IQ7+M [5] VCOP 0.000 0.193 0.617 1.279 8.894
11 - 202224****** IQ7+M [5] VCOP 0.000 0.190 0.614 1.285 8.978
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.191 0.661 1.391 8.327 0.000 kW
0.666 kWh
0.000 kW
2.665 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.185 0.665 1.380 8.096
14 - 202216****** IQ7+ [5] VCOP 0.000 0.189 0.673 1.396 8.382
15 - 202245****** IQ7+M [5] VCOP 0.000 0.191 0.667 1.378 8.247
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.17 V Current/Power -1.80 A (-95 W)
Remain Capacity/Energy 512.4 Ah (26.2 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 85.4 % State Of Health 100.0 %
Run Time 11d 20h 40m to empty Report Date 2021-08-28 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.