Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.718 kW
09/14/2025 09:58 (1936 days) Production Consumption NET Usage
Now 2.086 kW 0.368 kW -1.718 kW
Today 2.449 kWh (0.245 kW) 4.127 kWh (0.413 kW) 1.678 kWh (0.168 kW)
  - This Week 2.449 kWh (5.875 kWh/day) 4.127 kWh (9.901 kWh/day) 1.678 kWh (4.026 kWh/day)
  - This Month 288.218 kWh (21.483 kWh/day) 308.684 kWh (23.009 kWh/day) 20.466 kWh (1.525 kWh/day)
  - This Year 4.796 MWh (18.702 kWh/day) 5.479 MWh (21.369 kWh/day) 0.684 MWh (2.667 kWh/day)
Yesterday 22.447 kWh (0.936 kW) 24.168 kWh (1.008 kW) 1.721 kWh (0.072 kW)
Last 7 Days 148.841 kWh (21.265 kWh/day) 108.832 kWh (15.549 kWh/day) -40.009 kWh (-5.716 kWh/day)
Last 30 Days 687.521 kWh (22.918 kWh/day) 722.998 kWh (24.100 kWh/day) 35.477 kWh (1.183 kWh/day)
Last One Year 6.273 MWh (17.187 kWh/day) 7.101 MWh (19.456 kWh/day) 0.828 MWh (2.269 kWh/day)
Lifetime Since PTO 34.246 MWh (17.685 kW/day) 37.431 MWh (19.330 kW/day) 3.185 MWh (1.645 kW/day)
Lifetime Since Install 34.280 MWh 38.011 MWh 3.731 MWh
Voltage/Current 252.9 V / 8.2 A 252.9 V / 1.5 A 252.9 V / -6.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/07/2020 22:05 (10.0 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.693 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.209 1.102 1.059 7.090 0.000 kW
1.098 kWh
0.000 kW
6.590 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.206 1.083 1.038 6.916
03 - 202224****** IQ7+M [5] VCOP 0.000 0.209 1.102 1.054 6.978
04 - 202232****** IQ7+ [5] VCOP 0.000 0.209 1.091 1.050 6.928
05 - 202244****** IQ7+M [5] VCOP 0.000 0.208 1.108 1.068 7.068
06 - 202245****** IQ7+M [5] VCOP 0.000 0.206 1.105 1.055 7.117
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.254 1.288 1.328 8.413 0.000 kW
1.333 kWh
0.000 kW
6.665 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.256 1.135 1.204 7.715
09 - 202217****** IQ7+ [5] VCOP 0.000 0.253 1.460 1.425 8.981
10 - 202244****** IQ7+M [5] VCOP 0.000 0.253 1.433 1.415 8.965
11 - 202224****** IQ7+M [5] VCOP 0.000 0.252 1.349 1.373 8.651
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.118 0.573 0.513 3.931 0.000 kW
0.610 kWh
0.000 kW
2.439 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.117 0.628 0.572 4.238
14 - 202216****** IQ7+ [5] VCOP 0.000 0.117 0.627 0.571 4.256
15 - 202245****** IQ7+M [5] VCOP 0.000 0.115 0.611 0.558 4.175
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.02 V Current/Power 178.16 A (10.159 kW)
Remain Capacity/Energy 590.4 Ah (30.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.9 % State Of Health 98.5 %
Run Time - to full Report Date 2020-11-07 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.