Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.739 kW
07/01/2026 15:19 (2226 days) Production Consumption NET Usage
Now 3.618 kW 2.879 kW -0.739 kW
Today 19.839 kWh (1.293 kW) 19.706 kWh (1.285 kW) -0.133 kWh (-0.009 kW)
  - This Week 101.440 kWh (27.880 kWh/day) 93.846 kWh (25.793 kWh/day) -7.594 kWh (-2.087 kWh/day)
  - This Month 19.839 kWh (31.042 kWh/day) 19.706 kWh (30.834 kWh/day) -0.133 kWh (-0.208 kWh/day)
  - This Year 3.630 MWh (19.983 kWh/day) 3.306 MWh (18.204 kWh/day) -0.323 MWh (-1.779 kWh/day)
Yesterday 26.873 kWh (1.121 kW) 21.329 kWh (0.889 kW) -5.544 kWh (-0.231 kW)
Last 7 Days 168.332 kWh (24.047 kWh/day) 164.638 kWh (23.520 kWh/day) -3.694 kWh (-0.528 kWh/day)
Last 30 Days (06/01/2026) 869.075 kWh (28.969 kWh/day) 731.101 kWh (24.370 kWh/day) -137.974 kWh (-4.599 kWh/day)
Last One Year 6.696 MWh (18.346 kWh/day) 7.720 MWh (21.152 kWh/day) 1.024 MWh (2.805 kWh/day)
Lifetime Since PTO 39.195 MWh (17.603 kW/day) 42.817 MWh (19.230 kW/day) 3.622 MWh (1.627 kW/day)
Lifetime Since Install 39.229 MWh 43.397 MWh 4.168 MWh
Voltage/Current 247.6 V / 14.6 A 247.5 V / 11.6 A 247.5 V / -3.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 01/01/2026 23:28 (9.1 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 11.405 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.217 0.817 0.725 2.255 0.000 kW
0.796 kWh
0.000 kW
4.773 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.209 0.773 0.688 2.142
03 - 202224****** IQ7+M [5] VCOP 0.000 0.216 0.882 0.719 2.261
04 - 202232****** IQ7+ [5] VCOP 0.000 0.214 0.906 0.706 2.244
05 - 202244****** IQ7+M [5] VCOP 0.000 0.211 0.703 0.693 2.172
06 - 202245****** IQ7+M [5] VCOP 0.000 0.213 0.694 0.709 2.200
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.282 0.970 0.721 2.381 0.000 kW
1.119 kWh
0.000 kW
5.594 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.285 1.051 0.833 2.582
09 - 202217****** IQ7+ [5] VCOP 0.000 0.286 1.255 0.881 3.453
10 - 202244****** IQ7+M [5] VCOP 0.000 0.282 1.210 0.868 3.414
11 - 202224****** IQ7+M [5] VCOP 0.000 0.287 1.107 0.806 3.246
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.027 0.132 0.381 1.326 0.000 kW
0.139 kWh
0.000 kW
0.557 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.030 0.150 0.426 1.437
14 - 202216****** IQ7+ [5] VCOP 0.000 0.026 0.131 0.449 1.505
15 - 202245****** IQ7+M [5] VCOP 0.000 0.032 0.144 0.444 1.504
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.083 0.000 kW
0.160 kWh
0.000 kW
0.480 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.000 0.239 0.480 0.332 1.638
Panel Layout Each Group Production

Charger History
Voltage PV 2.48 V Voltage Charge 52.53 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 26.1 °C / 22.8 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2026-01-01 23:59
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.74 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 339.0 Ah (17.4 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 57.2 % State Of Health 98.9 %
Run Time 9d 10h 0m to empty Report Date 2026-01-01 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.