Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.617 kW
11/09/2025 22:10 (1992 days) Production Consumption NET Usage
Now 0.000 kW 0.617 kW 0.617 kW
Today 5.431 kWh (0.245 kW) 16.110 kWh (0.726 kW) 10.679 kWh (0.481 kW)
  - This Week 5.431 kWh (5.876 kWh/day) 16.110 kWh (17.429 kWh/day) 10.679 kWh (11.554 kWh/day)
  - This Month 115.464 kWh (12.938 kWh/day) 184.019 kWh (20.619 kWh/day) 68.555 kWh (7.682 kWh/day)
  - This Year 5.693 MWh (18.194 kWh/day) 6.516 MWh (20.824 kWh/day) 0.823 MWh (2.630 kWh/day)
Yesterday 15.394 kWh (0.641 kW) 24.543 kWh (1.022 kW) 9.149 kWh (0.381 kW)
Last 7 Days 93.095 kWh (13.299 kWh/day) 151.721 kWh (21.675 kWh/day) 58.626 kWh (8.375 kWh/day)
Last 30 Days 395.470 kWh (13.182 kWh/day) 463.753 kWh (15.459 kWh/day) 68.283 kWh (2.276 kWh/day)
Last One Year 6.171 MWh (16.908 kWh/day) 7.484 MWh (20.505 kWh/day) 1.313 MWh (3.597 kWh/day)
Lifetime Since PTO 35.144 MWh (17.634 kW/day) 38.469 MWh (19.302 kW/day) 3.325 MWh (1.668 kW/day)
Lifetime Since Install 35.178 MWh 39.049 MWh 3.871 MWh
Voltage/Current 248.6 V / 0.0 A 248.6 V / 2.5 A 248.6 V / 2.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/21/2020 21:13 (9.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 11.501 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.249 0.841 1.040 6.076 0.000 kW
0.818 kWh
0.000 kW
4.911 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.244 0.814 1.011 6.001
03 - 202224****** IQ7+M [0] ---- 0.000 0.249 0.803 1.003 6.008
04 - 202232****** IQ7+ [0] ---- 0.000 0.247 0.767 0.972 5.812
05 - 202244****** IQ7+M [0] ---- 0.000 0.251 0.846 1.060 6.035
06 - 202245****** IQ7+M [0] ---- 0.000 0.245 0.840 1.051 5.850
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.294 0.912 1.251 6.981 0.000 kW
0.912 kWh
0.000 kW
4.560 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 0.801 1.112 6.332
09 - 202217****** IQ7+ [0] ---- 0.000 0.295 0.973 1.347 7.592
10 - 202244****** IQ7+M [0] ---- 0.000 0.297 0.969 1.341 7.529
11 - 202224****** IQ7+M [0] ---- 0.000 0.295 0.904 1.261 7.121
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.138 0.482 0.434 3.128 0.000 kW
0.508 kWh
0.000 kW
2.030 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.138 0.520 0.502 3.444
14 - 202216****** IQ7+ [0] ---- 0.000 0.139 0.521 0.498 3.387
15 - 202245****** IQ7+M [0] ---- 0.000 0.134 0.507 0.484 3.332
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 52.13 V Current/Power 162.76 A (8.485 kW)
Remain Capacity/Energy 203.7 Ah (10.4 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 34.5 % State Of Health 98.5 %
Run Time 2h 22m to full Report Date 2020-11-21 23:16
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.