Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.352 kW
09/14/2025 13:43 (1936 days) Production Consumption NET Usage
Now 3.737 kW 0.385 kW -3.352 kW
Today 14.229 kWh (1.036 kW) 6.946 kWh (0.506 kW) -7.283 kWh (-0.530 kW)
  - This Week 14.229 kWh (24.856 kWh/day) 6.946 kWh (12.133 kWh/day) -7.283 kWh (-12.722 kWh/day)
  - This Month 299.998 kWh (22.105 kWh/day) 311.503 kWh (22.952 kWh/day) 11.505 kWh (0.848 kWh/day)
  - This Year 4.807 MWh (18.737 kWh/day) 5.482 MWh (21.367 kWh/day) 0.675 MWh (2.630 kWh/day)
Yesterday 22.447 kWh (0.936 kW) 24.168 kWh (1.008 kW) 1.721 kWh (0.072 kW)
Last 7 Days 148.841 kWh (21.265 kWh/day) 108.832 kWh (15.549 kWh/day) -40.009 kWh (-5.716 kWh/day)
Last 30 Days 687.521 kWh (22.918 kWh/day) 722.998 kWh (24.100 kWh/day) 35.477 kWh (1.183 kWh/day)
Last One Year 6.273 MWh (17.187 kWh/day) 7.101 MWh (19.456 kWh/day) 0.828 MWh (2.269 kWh/day)
Lifetime Since PTO 34.258 MWh (17.690 kW/day) 37.434 MWh (19.330 kW/day) 3.176 MWh (1.640 kW/day)
Lifetime Since Install 34.292 MWh 38.014 MWh 3.722 MWh
Voltage/Current 250.8 V / 14.9 A 250.8 V / 1.5 A 250.8 V / -13.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/10/2020 23:21 (12.2 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 12.443 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.259 0.867 1.169 11.496 0.000 kW
0.859 kWh
0.000 kW
5.156 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.256 0.856 1.159 11.384
03 - 202224****** IQ7+M [5] VCOP 0.000 0.256 0.869 1.179 11.594
04 - 202232****** IQ7+ [5] VCOP 0.000 0.257 0.861 1.170 11.572
05 - 202244****** IQ7+M [5] VCOP 0.000 0.256 0.848 1.131 11.038
06 - 202245****** IQ7+M [5] VCOP 0.000 0.256 0.855 1.145 11.038
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.251 0.826 1.147 11.472 0.000 kW
0.830 kWh
0.000 kW
4.152 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.248 0.822 1.130 11.179
09 - 202217****** IQ7+ [5] VCOP 0.000 0.253 0.833 1.142 11.385
10 - 202244****** IQ7+M [5] VCOP 0.000 0.257 0.840 1.170 11.690
11 - 202224****** IQ7+M [5] VCOP 0.000 0.253 0.832 1.159 11.658
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.231 0.781 1.034 10.020 0.000 kW
0.784 kWh
0.000 kW
3.135 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.228 0.782 1.030 9.822
14 - 202216****** IQ7+ [5] VCOP 0.000 0.229 0.791 1.049 10.056
15 - 202245****** IQ7+M [5] VCOP 0.000 0.226 0.781 1.035 9.902
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.