Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.222 kW
07/04/2026 09:23 (2229 days) Production Consumption NET Usage
Now 2.130 kW 2.352 kW 0.222 kW
Today 4.405 kWh (0.468 kW) 8.372 kWh (0.889 kW) 3.967 kWh (0.421 kW)
  - This Week 180.357 kWh (28.218 kWh/day) 210.289 kWh (32.902 kWh/day) 29.932 kWh (4.683 kWh/day)
  - This Month 98.756 kWh (29.114 kWh/day) 136.149 kWh (40.138 kWh/day) 37.393 kWh (11.024 kWh/day)
  - This Year 3.709 MWh (20.113 kWh/day) 3.423 MWh (18.563 kWh/day) -0.286 MWh (-1.549 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 188.093 kWh (26.870 kWh/day) 225.809 kWh (32.258 kWh/day) 37.716 kWh (5.388 kWh/day)
Last 30 Days (06/04/2026) 854.838 kWh (28.495 kWh/day) 816.175 kWh (27.206 kWh/day) -38.663 kWh (-1.289 kWh/day)
Last One Year 6.725 MWh (18.425 kWh/day) 7.762 MWh (21.266 kWh/day) 1.037 MWh (2.841 kWh/day)
Lifetime Since PTO 39.274 MWh (17.617 kW/day) 42.934 MWh (19.258 kW/day) 3.659 MWh (1.641 kW/day)
Lifetime Since Install 39.308 MWh 43.514 MWh 4.205 MWh
Voltage/Current 247.7 V / 8.6 A 247.7 V / 9.5 A 247.7 V / 0.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/29/2021 20:37 (14.6 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.736 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.300 2.122 2.034 12.169 0.000 kW
1.999 kWh
0.000 kW
11.994 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.295 2.000 1.961 11.711
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 2.002 1.973 11.841
04 - 202232****** IQ7+ [5] VCOP 0.000 0.298 2.025 1.998 11.916
05 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.817 1.782 10.932
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 2.028 1.980 11.832
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.299 1.816 1.742 10.689 0.000 kW
1.863 kWh
0.000 kW
9.315 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.302 1.864 1.820 11.073
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 1.848 1.793 10.960
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.888 1.856 11.222
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.900 1.860 11.263
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.259 2.145 2.024 12.034 0.000 kW
2.107 kWh
0.000 kW
8.427 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.264 2.055 1.942 11.622
14 - 202216****** IQ7+ [5] VCOP 0.000 0.258 2.128 2.019 12.089
15 - 202245****** IQ7+M [5] VCOP 0.000 0.254 2.099 1.989 11.901
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.21 V Current/Power -1.50 A (-79 W)
Remain Capacity/Energy 526.2 Ah (26.9 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 87.7 % State Of Health 100.0 %
Run Time 14d 14h 48m to empty Report Date 2021-06-29 23:58
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.