Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.688 kW
09/14/2025 15:08 (1936 days) Production Consumption NET Usage
Now 3.169 kW 2.481 kW -0.688 kW
Today 18.636 kWh (1.229 kW) 8.837 kWh (0.583 kW) -9.799 kWh (-0.646 kW)
  - This Week 18.636 kWh (29.488 kWh/day) 8.837 kWh (13.983 kWh/day) -9.799 kWh (-15.505 kWh/day)
  - This Month 304.405 kWh (22.331 kWh/day) 313.394 kWh (22.991 kWh/day) 8.989 kWh (0.659 kWh/day)
  - This Year 4.812 MWh (18.750 kWh/day) 5.484 MWh (21.370 kWh/day) 0.672 MWh (2.620 kWh/day)
Yesterday 22.447 kWh (0.936 kW) 24.168 kWh (1.008 kW) 1.721 kWh (0.072 kW)
Last 7 Days 148.841 kWh (21.265 kWh/day) 108.832 kWh (15.549 kWh/day) -40.009 kWh (-5.716 kWh/day)
Last 30 Days 687.521 kWh (22.918 kWh/day) 722.998 kWh (24.100 kWh/day) 35.477 kWh (1.183 kWh/day)
Last One Year 6.273 MWh (17.187 kWh/day) 7.101 MWh (19.456 kWh/day) 0.828 MWh (2.269 kWh/day)
Lifetime Since PTO 34.263 MWh (17.692 kW/day) 37.436 MWh (19.331 kW/day) 3.173 MWh (1.639 kW/day)
Lifetime Since Install 34.297 MWh 38.016 MWh 3.720 MWh
Voltage/Current 248.2 V / 12.8 A 248.3 V / 10.0 A 248.2 V / -2.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/31/2020 23:38 (12.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 15.259 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.256 1.066 1.841 11.146 0.000 kW
1.048 kWh
0.000 kW
6.287 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.255 1.054 1.822 10.967
03 - 202224****** IQ7+M [5] VCOP 0.000 0.260 1.074 1.859 11.182
04 - 202232****** IQ7+ [5] VCOP 0.000 0.258 1.063 1.870 11.209
05 - 202244****** IQ7+M [5] VCOP 0.000 0.256 1.003 1.818 10.623
06 - 202245****** IQ7+M [5] VCOP 0.000 0.253 1.027 1.815 10.771
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.263 1.003 1.823 10.814 0.000 kW
1.005 kWh
0.000 kW
5.025 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.263 0.978 1.895 10.786
09 - 202217****** IQ7+ [5] VCOP 0.000 0.264 1.008 1.801 10.794
10 - 202244****** IQ7+M [5] VCOP 0.000 0.261 1.023 1.892 11.040
11 - 202224****** IQ7+M [5] VCOP 0.000 0.261 1.013 1.914 11.031
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.205 0.982 1.598 9.945 0.000 kW
0.987 kWh
0.000 kW
3.948 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.208 0.981 1.528 9.696
14 - 202216****** IQ7+ [5] VCOP 0.000 0.208 0.998 1.598 9.951
15 - 202245****** IQ7+M [5] VCOP 0.000 0.203 0.986 1.571 9.785
wind 16 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.62 V Current/Power 179.90 A (10.365 kW)
Remain Capacity/Energy 589.8 Ah (30.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.8 % State Of Health 98.5 %
Run Time - to full Report Date 2020-09-01 00:00
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 57.62 V Cell (MIN/MAX) 3.584 V / 3.607 V (0.023 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 196.6 Ah (10.1 kWh) Full Capacity/Energy 197.0 Ah (10.1 kWh)
State Of Charge 99.8 % State Of Health 98.5 %
Temperature 24.5 °C Cycle 25
MOSFET CFET = ON, DFET = ON Reported 2020-09-01 00:00
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.601 V 3.596 V 3.599 V 3.601 V 3.600 V 3.602 V 3.601 V 3.603 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.584 V 3.588 V 3.605 V 3.606 V 3.606 V 3.607 V 3.604 V 3.605 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -