Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 3.496 kW
09/14/2025 13:25 (1936 days) Production Consumption NET Usage
Now 3.924 kW 0.428 kW -3.496 kW
Today 13.123 kWh (0.975 kW) 6.827 kWh (0.507 kW) -6.296 kWh (-0.468 kW)
  - This Week 13.123 kWh (23.412 kWh/day) 6.827 kWh (12.179 kWh/day) -6.296 kWh (-11.232 kWh/day)
  - This Month 298.892 kWh (22.043 kWh/day) 311.384 kWh (22.964 kWh/day) 12.492 kWh (0.921 kWh/day)
  - This Year 4.806 MWh (18.733 kWh/day) 5.482 MWh (21.368 kWh/day) 0.676 MWh (2.634 kWh/day)
Yesterday 22.447 kWh (0.936 kW) 24.168 kWh (1.008 kW) 1.721 kWh (0.072 kW)
Last 7 Days 148.841 kWh (21.265 kWh/day) 108.832 kWh (15.549 kWh/day) -40.009 kWh (-5.716 kWh/day)
Last 30 Days 687.521 kWh (22.918 kWh/day) 722.998 kWh (24.100 kWh/day) 35.477 kWh (1.183 kWh/day)
Last One Year 6.273 MWh (17.187 kWh/day) 7.101 MWh (19.456 kWh/day) 0.828 MWh (2.269 kWh/day)
Lifetime Since PTO 34.257 MWh (17.690 kW/day) 37.434 MWh (19.330 kW/day) 3.177 MWh (1.641 kW/day)
Lifetime Since Install 34.291 MWh 38.014 MWh 3.723 MWh
Voltage/Current 251.0 V / 15.6 A 250.9 V / 1.7 A 251.0 V / -13.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/30/2020 23:41 (12.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.644 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.298 1.841 0.722 11.182 0.000 kW
1.838 kWh
0.000 kW
11.025 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.822 0.713 10.998
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.859 0.728 11.210
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.870 0.718 11.236
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.818 0.709 10.619
06 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.815 0.712 10.800
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.823 0.710 10.873 0.000 kW
1.865 kWh
0.000 kW
9.324 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.895 0.737 10.780
09 - 202217****** IQ7+ [5] VCOP 0.000 0.297 1.801 0.703 10.875
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.892 0.745 11.056
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.914 0.740 11.028
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.252 1.598 0.572 9.925 0.000 kW
1.574 kWh
0.000 kW
6.295 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.257 1.528 0.556 9.676
14 - 202216****** IQ7+ [5] VCOP 0.000 0.253 1.598 0.584 9.945
15 - 202245****** IQ7+M [5] VCOP 0.000 0.245 1.571 0.574 9.787
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.60 V Current/Power 179.82 A (10.358 kW)
Remain Capacity/Energy 590.7 Ah (30.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.9 % State Of Health 98.5 %
Run Time - to full Report Date 2020-08-31 00:00
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.