Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.798 kW
07/04/2026 09:21 (2229 days) Production Consumption NET Usage
Now 2.096 kW 0.298 kW -1.798 kW
Today 4.330 kWh (0.461 kW) 8.343 kWh (0.889 kW) 4.013 kWh (0.428 kW)
  - This Week 180.282 kWh (28.213 kWh/day) 210.260 kWh (32.905 kWh/day) 29.978 kWh (4.691 kWh/day)
  - This Month 98.681 kWh (29.104 kWh/day) 136.120 kWh (40.147 kWh/day) 37.439 kWh (11.042 kWh/day)
  - This Year 3.709 MWh (20.112 kWh/day) 3.423 MWh (18.563 kWh/day) -0.286 MWh (-1.549 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 188.071 kWh (26.867 kWh/day) 225.780 kWh (32.254 kWh/day) 37.709 kWh (5.387 kWh/day)
Last 30 Days (06/04/2026) 854.870 kWh (28.496 kWh/day) 816.107 kWh (27.204 kWh/day) -38.763 kWh (-1.292 kWh/day)
Last One Year 6.725 MWh (18.425 kWh/day) 7.762 MWh (21.266 kWh/day) 1.037 MWh (2.840 kWh/day)
Lifetime Since PTO 39.274 MWh (17.617 kW/day) 42.934 MWh (19.258 kW/day) 3.659 MWh (1.641 kW/day)
Lifetime Since Install 39.308 MWh 43.514 MWh 4.206 MWh
Voltage/Current 248.4 V / 8.4 A 248.5 V / 1.2 A 248.4 V / -7.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/08/2021 23:04 (14.7 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 16.505 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.299 1.157 1.443 10.770 0.000 kW
1.090 kWh
0.000 kW
6.542 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.108 1.365 10.360
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.102 1.354 10.404
04 - 202232****** IQ7+ [5] VCOP 0.000 0.299 1.118 1.377 10.467
05 - 202244****** IQ7+M [5] VCOP 0.000 0.298 0.939 1.163 9.545
06 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.117 1.381 10.423
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.299 0.951 1.199 9.377 0.000 kW
0.948 kWh
0.000 kW
4.741 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.297 0.935 1.193 9.579
09 - 202217****** IQ7+ [5] VCOP 0.000 0.295 0.951 1.209 9.570
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 0.955 1.216 9.790
11 - 202224****** IQ7+M [5] VCOP 0.000 0.293 0.948 1.208 9.789
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.287 1.303 1.656 10.766 0.000 kW
1.306 kWh
0.000 kW
5.222 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.286 1.301 1.645 10.520
14 - 202216****** IQ7+ [5] VCOP 0.000 0.290 1.315 1.659 10.801
15 - 202245****** IQ7+M [5] VCOP 0.000 0.289 1.303 1.633 10.646
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.36 V Current/Power -1.80 A (-96 W)
Remain Capacity/Energy 530.4 Ah (27.2 kWh) Full Capacity/Energy 600.0 Ah (30.7 kWh)
State Of Charge 88.4 % State Of Health 100.0 %
Run Time 12d 6h 40m to empty Report Date 2021-06-08 23:55
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.