Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.630 kW
07/15/2025 09:59 (1875 days) Production Consumption NET Usage
Now 1.103 kW 0.473 kW -0.630 kW
Today 2.776 kWh (0.277 kW) 7.800 kWh (0.779 kW) 5.024 kWh (0.502 kW)
  - This Week 41.948 kWh (17.354 kWh/day) 72.287 kWh (29.906 kWh/day) 30.339 kWh (12.552 kWh/day)
  - This Month 339.026 kWh (23.516 kWh/day) 569.145 kWh (39.477 kWh/day) 230.119 kWh (15.962 kWh/day)
  - This Year 3.369 MWh (17.239 kWh/day) 3.696 MWh (18.915 kWh/day) 0.328 MWh (1.677 kWh/day)
Yesterday 18.325 kWh (0.763 kW) 30.564 kWh (1.273 kW) 12.239 kWh (0.510 kW)
Last 7 Days 157.238 kWh (22.464 kWh/day) 281.273 kWh (40.184 kWh/day) 124.035 kWh (17.720 kWh/day)
Last 30 Days 658.132 kWh (21.939 kWh/day) 1078.022 kWh (35.936 kWh/day) 419.890 kWh (13.997 kWh/day)
Last One Year 6.261 MWh (17.153 kWh/day) 6.541 MWh (17.922 kWh/day) 0.280 MWh (0.768 kWh/day)
Lifetime Since PTO 32.820 MWh (17.500 kW/day) 35.648 MWh (19.008 kW/day) 2.829 MWh (1.508 kW/day)
Lifetime Since Install 32.854 MWh 36.228 MWh 3.375 MWh
Voltage/Current 247.2 V / 4.5 A 247.1 V / 1.9 A 247.1 V / -2.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/17/2020 22:17 (14.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 30.241 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.087 2.338 14.397 0.000 kW
1.999 kWh
0.000 kW
11.995 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.295 2.015 2.261 13.912
03 - 202224****** IQ7+M [5] VCOP 0.000 0.295 2.006 2.238 13.845
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.028 2.269 13.979
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.813 2.049 12.687
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 2.045 2.295 14.113
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.843 2.018 12.550 0.000 kW
1.840 kWh
0.000 kW
9.202 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.841 2.134 12.974
09 - 202217****** IQ7+ [5] VCOP 0.000 0.294 1.839 2.065 12.706
10 - 202244****** IQ7+M [5] VCOP 0.000 0.293 1.843 2.141 13.039
11 - 202224****** IQ7+M [5] VCOP 0.000 0.293 1.836 2.153 13.063
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.278 2.268 2.357 14.687 0.000 kW
2.261 kWh
0.000 kW
9.044 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.278 2.261 2.269 14.270
14 - 202216****** IQ7+ [5] VCOP 0.000 0.278 2.279 2.362 14.709
15 - 202245****** IQ7+M [5] VCOP 0.000 0.273 2.236 2.323 14.446
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 223

Battery History
Voltage 53.37 V Current/Power 166.64 A (8.893 kW)
Remain Capacity/Energy 575.7 Ah (29.5 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 99.7 % State Of Health 96.2 %
Run Time - to full Report Date 2020-06-17 23:56
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.37 V Cell (MIN/MAX) 3.329 V / 3.340 V (0.011 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 191.9 Ah (9.8 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 99.7 % State Of Health 96.2 %
Temperature 23.5 °C Cycle 22
MOSFET CFET = ON, DFET = ON Reported 2020-06-17 23:56
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.330 V 3.329 V 3.333 V 3.330 V 3.335 V 3.334 V 3.333 V 3.336 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.337 V 3.335 V 3.337 V 3.335 V 3.338 V 3.337 V 3.340 V 3.340 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -