Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.877 kW
09/14/2025 15:09 (1936 days) Production Consumption NET Usage
Now 3.418 kW 2.541 kW -0.877 kW
Today 18.666 kWh (1.230 kW) 8.860 kWh (0.584 kW) -9.806 kWh (-0.646 kW)
  - This Week 18.666 kWh (29.518 kWh/day) 8.860 kWh (14.011 kWh/day) -9.806 kWh (-15.507 kWh/day)
  - This Month 304.435 kWh (22.333 kWh/day) 313.417 kWh (22.992 kWh/day) 8.982 kWh (0.659 kWh/day)
  - This Year 4.812 MWh (18.750 kWh/day) 5.484 MWh (21.370 kWh/day) 0.672 MWh (2.620 kWh/day)
Yesterday 22.447 kWh (0.936 kW) 24.168 kWh (1.008 kW) 1.721 kWh (0.072 kW)
Last 7 Days 148.841 kWh (21.265 kWh/day) 108.832 kWh (15.549 kWh/day) -40.009 kWh (-5.716 kWh/day)
Last 30 Days 687.521 kWh (22.918 kWh/day) 722.998 kWh (24.100 kWh/day) 35.477 kWh (1.183 kWh/day)
Last One Year 6.273 MWh (17.187 kWh/day) 7.101 MWh (19.456 kWh/day) 0.828 MWh (2.269 kWh/day)
Lifetime Since PTO 34.263 MWh (17.692 kW/day) 37.436 MWh (19.331 kW/day) 3.173 MWh (1.639 kW/day)
Lifetime Since Install 34.297 MWh 38.016 MWh 3.720 MWh
Voltage/Current 248.4 V / 13.8 A 248.3 V / 10.2 A 248.4 V / -3.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/08/2020 20:10 (13.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 20.522 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.296 1.434 1.160 10.237 0.000 kW
1.423 kWh
0.000 kW
8.535 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.418 1.146 9.966
03 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.438 1.163 10.115
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.429 1.156 10.165
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.402 1.057 9.507
06 - 202245****** IQ7+M [5] VCOP 0.000 0.297 1.414 1.141 9.980
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.297 1.373 1.029 9.527 0.000 kW
1.392 kWh
0.000 kW
6.958 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.394 1.015 9.743
09 - 202217****** IQ7+ [5] VCOP 0.000 0.296 1.385 1.034 9.602
10 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.400 1.041 9.842
11 - 202224****** IQ7+M [5] VCOP 0.000 0.297 1.406 1.032 9.807
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.287 1.261 1.165 9.526 0.000 kW
1.257 kWh
0.000 kW
5.028 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.287 1.233 1.166 9.182
14 - 202216****** IQ7+ [5] VCOP 0.000 0.288 1.276 1.178 9.576
15 - 202245****** IQ7+M [5] VCOP 0.000 0.284 1.258 1.166 9.431
wind 16 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.61 V Current/Power 179.87 A (10.363 kW)
Remain Capacity/Energy 571.5 Ah (29.3 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 99.0 % State Of Health 96.2 %
Run Time 1m to full Report Date 2020-08-08 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 57.61 V Cell (MIN/MAX) 3.588 V / 3.608 V (0.020 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 190.5 Ah (9.8 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 99.0 % State Of Health 96.2 %
Temperature 25.5 °C Cycle 24
MOSFET CFET = ON, DFET = ON Reported 2020-08-08 23:59
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.597 V 3.597 V 3.600 V 3.600 V 3.602 V 3.602 V 3.601 V 3.588 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.599 V 3.600 V 3.602 V 3.606 V 3.604 V 3.603 V 3.597 V 3.608 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -