Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.949 kW
09/14/2025 16:05 (1936 days) Production Consumption NET Usage
Now 1.656 kW 0.707 kW -0.949 kW
Today 21.339 kWh (1.324 kW) 11.470 kWh (0.712 kW) -9.869 kWh (-0.612 kW)
  - This Week 21.339 kWh (31.769 kWh/day) 11.470 kWh (17.076 kWh/day) -9.869 kWh (-14.693 kWh/day)
  - This Month 307.108 kWh (22.464 kWh/day) 316.027 kWh (23.117 kWh/day) 8.919 kWh (0.652 kWh/day)
  - This Year 4.814 MWh (18.757 kWh/day) 5.487 MWh (21.377 kWh/day) 0.672 MWh (2.619 kWh/day)
Yesterday 22.447 kWh (0.936 kW) 24.168 kWh (1.008 kW) 1.721 kWh (0.072 kW)
Last 7 Days 148.841 kWh (21.265 kWh/day) 108.832 kWh (15.549 kWh/day) -40.009 kWh (-5.716 kWh/day)
Last 30 Days 687.521 kWh (22.918 kWh/day) 722.998 kWh (24.100 kWh/day) 35.477 kWh (1.183 kWh/day)
Last One Year 6.273 MWh (17.187 kWh/day) 7.101 MWh (19.456 kWh/day) 0.828 MWh (2.269 kWh/day)
Lifetime Since PTO 34.265 MWh (17.693 kW/day) 37.439 MWh (19.331 kW/day) 3.173 MWh (1.639 kW/day)
Lifetime Since Install 34.299 MWh 38.019 MWh 3.719 MWh
Voltage/Current 248.4 V / 6.7 A 248.5 V / 2.8 A 248.5 V / -3.8 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/03/2020 21:18 (13.7 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.140 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.294 2.042 1.384 12.019 0.000 kW
1.974 kWh
0.000 kW
11.842 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.293 1.968 1.369 11.644
03 - 202224****** IQ7+M [5] VCOP 0.000 0.294 1.990 1.394 11.775
04 - 202232****** IQ7+ [5] VCOP 0.000 0.295 2.016 1.387 11.871
05 - 202244****** IQ7+M [5] VCOP 0.000 0.293 1.852 1.375 11.009
06 - 202245****** IQ7+M [5] VCOP 0.000 0.292 1.974 1.372 11.692
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.295 1.900 1.371 10.883 0.000 kW
1.896 kWh
0.000 kW
9.481 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.890 1.415 11.296
09 - 202217****** IQ7+ [5] VCOP 0.000 0.294 1.893 1.386 11.025
10 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.903 1.427 11.390
11 - 202224****** IQ7+M [5] VCOP 0.000 0.295 1.894 1.422 11.401
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.248 1.984 1.123 11.432 0.000 kW
1.954 kWh
0.000 kW
7.817 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.246 1.912 1.079 10.986
14 - 202216****** IQ7+ [5] VCOP 0.000 0.248 1.976 1.140 11.446
15 - 202245****** IQ7+M [5] VCOP 0.000 0.243 1.945 1.120 11.258
wind 16 - 122214****** IQ7PD [4] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_all.png". Check that the process running PHP has enough permission.