Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.236 kW
11/10/2025 05:03 (1993 days) Production Consumption NET Usage
Now 0.000 kW 0.236 kW 0.236 kW
Today 0.000 kWh (0.000 kW) 1.622 kWh (0.321 kW) 1.622 kWh (0.321 kW)
  - This Week 5.431 kWh (4.485 kWh/day) 18.926 kWh (15.629 kWh/day) 13.495 kWh (11.144 kWh/day)
  - This Month 115.464 kWh (12.535 kWh/day) 186.835 kWh (20.283 kWh/day) 71.371 kWh (7.748 kWh/day)
  - This Year 5.693 MWh (18.178 kWh/day) 6.519 MWh (20.814 kWh/day) 0.826 MWh (2.637 kWh/day)
Yesterday 5.431 kWh (0.226 kW) 17.304 kWh (0.721 kW) 11.873 kWh (0.495 kW)
Last 7 Days 81.355 kWh (11.621 kWh/day) 142.708 kWh (20.384 kWh/day) 61.353 kWh (8.764 kWh/day)
Last 30 Days 381.780 kWh (12.726 kWh/day) 467.869 kWh (15.595 kWh/day) 86.089 kWh (2.870 kWh/day)
Last One Year 6.162 MWh (16.883 kWh/day) 7.484 MWh (20.505 kWh/day) 1.322 MWh (3.622 kWh/day)
Lifetime Since PTO 35.144 MWh (17.632 kW/day) 38.472 MWh (19.301 kW/day) 3.328 MWh (1.669 kW/day)
Lifetime Since Install 35.178 MWh 39.052 MWh 3.874 MWh
Voltage/Current 250.2 V / 0.0 A 250.1 V / 0.9 A 250.2 V / 0.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/30/2020 22:41 (12.9 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.644 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.298 1.841 0.722 11.182 0.000 kW
1.838 kWh
0.000 kW
11.025 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.822 0.713 10.998
03 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.859 0.728 11.210
04 - 202232****** IQ7+ [0] ---- 0.000 0.297 1.870 0.718 11.236
05 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.818 0.709 10.619
06 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.815 0.712 10.800
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.296 1.823 0.710 10.873 0.000 kW
1.865 kWh
0.000 kW
9.324 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.895 0.737 10.780
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 1.801 0.703 10.875
10 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.892 0.745 11.056
11 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.914 0.740 11.028
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.252 1.598 0.572 9.925 0.000 kW
1.574 kWh
0.000 kW
6.295 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.257 1.528 0.556 9.676
14 - 202216****** IQ7+ [0] ---- 0.000 0.253 1.598 0.584 9.945
15 - 202245****** IQ7+M [0] ---- 0.000 0.245 1.571 0.574 9.787
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.61 V Current/Power 179.86 A (10.362 kW)
Remain Capacity/Energy 590.7 Ah (30.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.9 % State Of Health 98.5 %
Run Time - to full Report Date 2020-08-30 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.