Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.582 kW
07/04/2026 10:32 (2229 days) Production Consumption NET Usage
Now 3.084 kW 2.502 kW -0.582 kW
Today 7.324 kWh (0.693 kW) 9.960 kWh (0.943 kW) 2.636 kWh (0.249 kW)
  - This Week 183.276 kWh (28.462 kWh/day) 211.877 kWh (32.904 kWh/day) 28.601 kWh (4.442 kWh/day)
  - This Month 101.675 kWh (29.558 kWh/day) 137.737 kWh (40.041 kWh/day) 36.062 kWh (10.483 kWh/day)
  - This Year 3.712 MWh (20.123 kWh/day) 3.425 MWh (18.567 kWh/day) -0.287 MWh (-1.556 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 189.254 kWh (27.036 kWh/day) 226.271 kWh (32.324 kWh/day) 37.017 kWh (5.288 kWh/day)
Last 30 Days (06/04/2026) 854.446 kWh (28.482 kWh/day) 818.329 kWh (27.278 kWh/day) -36.117 kWh (-1.204 kWh/day)
Last One Year 6.725 MWh (18.425 kWh/day) 7.763 MWh (21.269 kWh/day) 1.038 MWh (2.843 kWh/day)
Lifetime Since PTO 39.277 MWh (17.618 kW/day) 42.935 MWh (19.258 kW/day) 3.658 MWh (1.641 kW/day)
Lifetime Since Install 39.311 MWh 43.515 MWh 4.204 MWh
Voltage/Current 247.6 V / 12.5 A 247.5 V / 10.1 A 247.6 V / -2.4 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 04/20/2021 23:50 (13.2 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 29.584 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.299 2.063 1.179 8.000 0.000 kW
2.017 kWh
0.000 kW
12.101 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.297 2.010 1.131 7.738
03 - 202224****** IQ7+M [5] VCOP 0.000 0.299 2.065 1.181 8.005
04 - 202232****** IQ7+ [5] VCOP 0.000 0.298 2.086 1.212 8.087
05 - 202244****** IQ7+M [5] VCOP 0.000 0.298 1.909 1.019 7.273
06 - 202245****** IQ7+M [5] VCOP 0.000 0.298 1.968 1.089 7.543
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.299 1.951 1.042 7.360 0.000 kW
1.988 kWh
0.000 kW
9.939 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.299 1.971 1.009 7.191
09 - 202217****** IQ7+ [5] VCOP 0.000 0.301 1.964 1.045 7.387
10 - 202244****** IQ7+M [5] VCOP 0.000 0.301 2.020 1.094 7.555
11 - 202224****** IQ7+M [5] VCOP 0.000 0.299 2.034 1.080 7.512
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.273 1.914 1.305 8.156 0.000 kW
1.886 kWh
0.000 kW
7.545 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.272 1.845 1.280 8.010
14 - 202216****** IQ7+ [5] VCOP 0.000 0.272 1.909 1.307 8.179
15 - 202245****** IQ7+M [5] VCOP 0.000 0.264 1.877 1.293 8.062
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.