Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 9.371 kW
09/14/2025 18:44 (1936 days) Production Consumption NET Usage
Now 0.037 kW 9.408 kW 9.371 kW
Today 23.149 kWh (1.233 kW) 27.968 kWh (1.490 kW) 4.819 kWh (0.257 kW)
  - This Week 23.149 kWh (29.603 kWh/day) 27.968 kWh (35.766 kWh/day) 4.819 kWh (6.163 kWh/day)
  - This Month 308.918 kWh (22.416 kWh/day) 332.525 kWh (24.129 kWh/day) 23.607 kWh (1.713 kWh/day)
  - This Year 4.816 MWh (18.756 kWh/day) 5.503 MWh (21.432 kWh/day) 0.687 MWh (2.675 kWh/day)
Yesterday 22.447 kWh (0.936 kW) 24.168 kWh (1.008 kW) 1.721 kWh (0.072 kW)
Last 7 Days 148.841 kWh (21.265 kWh/day) 108.832 kWh (15.549 kWh/day) -40.009 kWh (-5.716 kWh/day)
Last 30 Days 687.521 kWh (22.918 kWh/day) 722.998 kWh (24.100 kWh/day) 35.477 kWh (1.183 kWh/day)
Last One Year 6.273 MWh (17.187 kWh/day) 7.101 MWh (19.456 kWh/day) 0.828 MWh (2.269 kWh/day)
Lifetime Since PTO 34.267 MWh (17.693 kW/day) 37.455 MWh (19.339 kW/day) 3.188 MWh (1.646 kW/day)
Lifetime Since Install 34.301 MWh 38.035 MWh 3.734 MWh
Voltage/Current 247.0 V / 0.1 A 247.0 V / 38.1 A 247.0 V / 37.9 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/12/2020 21:41 (14.6 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 31.058 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.297 2.176 0.806 12.461 0.000 kW
2.065 kWh
0.000 kW
12.388 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.297 2.086 0.795 12.053
03 - 202224****** IQ7+M [5] VCOP 0.000 0.296 2.059 0.812 12.037
04 - 202232****** IQ7+ [5] VCOP 0.000 0.296 2.081 0.800 12.107
05 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.864 0.791 11.076
06 - 202245****** IQ7+M [5] VCOP 0.000 0.296 2.121 0.798 12.202
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.296 1.884 0.696 10.783 0.000 kW
1.901 kWh
0.000 kW
9.503 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.296 1.907 0.759 11.214
09 - 202217****** IQ7+ [5] VCOP 0.000 0.298 1.897 0.729 10.989
10 - 202244****** IQ7+M [5] VCOP 0.000 0.297 1.910 0.771 11.306
11 - 202224****** IQ7+M [5] VCOP 0.000 0.296 1.906 0.780 11.340
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.291 2.324 0.702 12.416 0.000 kW
2.292 kWh
0.000 kW
9.167 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.292 2.274 0.678 12.073
14 - 202216****** IQ7+ [5] VCOP 0.000 0.290 2.309 0.716 12.428
15 - 202245****** IQ7+M [5] VCOP 0.000 0.287 2.260 0.702 12.201
wind 16 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.29 V Current/Power 166.42 A (8.869 kW)
Remain Capacity/Energy 565.8 Ah (29.0 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 98.0 % State Of Health 96.2 %
Run Time 4m to full Report Date 2020-06-12 23:15
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.