Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 1.364 kW
07/04/2026 13:48 (2229 days) Production Consumption NET Usage
Now 4.171 kW 2.807 kW -1.364 kW
Today 19.280 kWh (1.393 kW) 17.371 kWh (1.255 kW) -1.909 kWh (-0.138 kW)
  - This Week 195.232 kWh (29.690 kWh/day) 219.288 kWh (33.348 kWh/day) 24.056 kWh (3.658 kWh/day)
  - This Month 113.631 kWh (31.773 kWh/day) 145.148 kWh (40.586 kWh/day) 31.517 kWh (8.813 kWh/day)
  - This Year 3.723 MWh (20.173 kWh/day) 3.432 MWh (18.594 kWh/day) -0.292 MWh (-1.579 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 198.894 kWh (28.413 kWh/day) 230.797 kWh (32.971 kWh/day) 31.903 kWh (4.558 kWh/day)
Last 30 Days (06/04/2026) 853.243 kWh (28.441 kWh/day) 823.110 kWh (27.437 kWh/day) -30.133 kWh (-1.004 kWh/day)
Last One Year 6.725 MWh (18.424 kWh/day) 7.755 MWh (21.245 kWh/day) 1.030 MWh (2.821 kWh/day)
Lifetime Since PTO 39.289 MWh (17.622 kW/day) 42.943 MWh (19.260 kW/day) 3.654 MWh (1.639 kW/day)
Lifetime Since Install 39.323 MWh 43.523 MWh 4.200 MWh
Voltage/Current 248.6 V / 16.8 A 248.5 V / 11.3 A 248.5 V / -5.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 03/02/2021 23:03 (11.1 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.922 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.298 1.988 0.386 5.919 0.000 kW
1.943 kWh
0.000 kW
11.658 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.295 1.924 0.364 5.606
03 - 202224****** IQ7+M [5] VCOP 0.000 0.300 1.969 0.383 5.771
04 - 202232****** IQ7+ [5] VCOP 0.000 0.297 1.953 0.380 5.736
05 - 202244****** IQ7+M [5] VCOP 0.000 0.296 1.912 0.356 5.814
06 - 202245****** IQ7+M [5] VCOP 0.000 0.295 1.912 0.369 5.864
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.300 2.062 0.397 6.362 0.000 kW
2.072 kWh
0.000 kW
10.362 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.301 1.898 0.398 5.917
09 - 202217****** IQ7+ [5] VCOP 0.000 0.300 2.106 0.370 6.589
10 - 202244****** IQ7+M [5] VCOP 0.000 0.299 2.160 0.411 6.954
11 - 202224****** IQ7+M [5] VCOP 0.000 0.300 2.136 0.406 6.619
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.202 1.215 0.329 4.116 0.000 kW
1.225 kWh
0.000 kW
4.902 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.200 1.220 0.330 4.061
14 - 202216****** IQ7+ [5] VCOP 0.000 0.201 1.246 0.337 4.102
15 - 202245****** IQ7+M [5] VCOP 0.000 0.197 1.221 0.331 4.081
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Battery History
Voltage 53.99 V Current/Power -1.80 A (-97 W)
Remain Capacity/Energy 522.6 Ah (26.8 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 88.4 % State Of Health 98.5 %
Run Time 12d 2h 20m to empty Report Date 2021-03-02 21:52
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.