Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.130 kW
11/10/2025 08:24 (1993 days) Production Consumption NET Usage
Now 0.293 kW 0.163 kW -0.130 kW
Today 0.344 kWh (0.041 kW) 4.445 kWh (0.529 kW) 4.101 kWh (0.488 kW)
  - This Week 5.775 kWh (4.276 kWh/day) 21.749 kWh (16.104 kWh/day) 15.974 kWh (11.828 kWh/day)
  - This Month 115.808 kWh (12.385 kWh/day) 189.658 kWh (20.282 kWh/day) 73.850 kWh (7.898 kWh/day)
  - This Year 5.694 MWh (18.171 kWh/day) 6.522 MWh (20.814 kWh/day) 0.828 MWh (2.643 kWh/day)
Yesterday 5.431 kWh (0.226 kW) 17.304 kWh (0.721 kW) 11.873 kWh (0.495 kW)
Last 7 Days 81.355 kWh (11.621 kWh/day) 142.708 kWh (20.384 kWh/day) 61.353 kWh (8.764 kWh/day)
Last 30 Days 381.780 kWh (12.726 kWh/day) 467.869 kWh (15.595 kWh/day) 86.089 kWh (2.870 kWh/day)
Last One Year 6.162 MWh (16.883 kWh/day) 7.484 MWh (20.505 kWh/day) 1.322 MWh (3.622 kWh/day)
Lifetime Since PTO 35.145 MWh (17.631 kW/day) 38.475 MWh (19.301 kW/day) 3.330 MWh (1.671 kW/day)
Lifetime Since Install 35.179 MWh 39.055 MWh 3.876 MWh
Voltage/Current 248.9 V / 1.2 A 249.0 V / 0.7 A 249.0 V / -0.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/11/2020 23:48 (14.8 hours) Number of Devices 16 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 11.335 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.218 0.806 2.203 13.464 0.000 kW
0.800 kWh
0.000 kW
4.802 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.215 0.795 2.152 13.003
03 - 202224****** IQ7+M [5] VCOP 0.000 0.220 0.812 2.164 12.966
04 - 202232****** IQ7+ [5] VCOP 0.000 0.218 0.800 2.190 13.060
05 - 202244****** IQ7+M [5] VCOP 0.000 0.217 0.791 1.988 11.892
06 - 202245****** IQ7+M [5] VCOP 0.000 0.215 0.798 2.175 13.162
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.228 0.696 2.001 11.691 0.000 kW
0.747 kWh
0.000 kW
3.735 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.231 0.759 2.019 12.064
09 - 202217****** IQ7+ [5] VCOP 0.000 0.230 0.729 2.001 11.869
10 - 202244****** IQ7+M [5] VCOP 0.000 0.231 0.771 2.028 12.158
11 - 202224****** IQ7+M [5] VCOP 0.000 0.228 0.780 2.029 12.173
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.196 0.702 2.146 13.649 0.000 kW
0.700 kWh
0.000 kW
2.798 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.197 0.678 2.105 13.328
14 - 202216****** IQ7+ [5] VCOP 0.000 0.198 0.716 2.164 13.648
15 - 202245****** IQ7+M [5] VCOP 0.000 0.196 0.702 2.135 13.399
wind 16 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 53.35 V Current/Power 166.60 A (8.889 kW)
Remain Capacity/Energy 566.4 Ah (29.0 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 98.1 % State Of Health 96.2 %
Run Time 3m to full Report Date 2020-06-11 23:09
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 53.35 V Cell (MIN/MAX) 3.328 V / 3.339 V (0.011 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 188.8 Ah (9.7 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 98.1 % State Of Health 96.2 %
Temperature 23.5 °C Cycle 22
MOSFET CFET = ON, DFET = ON Reported 2020-06-11 23:09
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.329 V 3.328 V 3.332 V 3.330 V 3.334 V 3.333 V 3.332 V 3.335 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.336 V 3.334 V 3.336 V 3.334 V 3.337 V 3.337 V 3.339 V 3.339 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -