| Date Offset [+30][+10][+05][+01][-01][-05][-10] |
|---|
| Exporting to grid by 0.094 kW | |||
|---|---|---|---|
| 05/14/2026 06:09 (2178 days) | Production | Consumption | NET Usage |
| Now | 0.335 kW | 0.241 kW | -0.094 kW |
| Today | 1.957 kWh (0.318 kW) | 2.188 kWh (0.355 kW) | 0.231 kWh (0.037 kW) |
| - This Week | 109.258 kWh (25.666 kWh/day) | 53.550 kWh (12.579 kWh/day) | -55.708 kWh (-13.086 kWh/day) |
| - This Month | 327.333 kWh (24.692 kWh/day) | 170.687 kWh (12.876 kWh/day) | -156.646 kWh (-11.816 kWh/day) |
| - This Year | 2.280 MWh (17.113 kWh/day) | 2.230 MWh (16.738 kWh/day) | -0.050 MWh (-0.375 kWh/day) |
| Yesterday | 25.506 kWh (1.062 kW) | 14.443 kWh (0.601 kW) | -11.063 kWh (-0.461 kW) |
| Last 7 Days | 173.726 kWh (24.818 kWh/day) | 127.087 kWh (18.155 kWh/day) | -46.639 kWh (-6.663 kWh/day) |
| Last 30 Days (04/14/2026) | 708.188 kWh (23.606 kWh/day) | 432.935 kWh (14.431 kWh/day) | -275.253 kWh (-9.175 kWh/day) |
| Last One Year | 6.316 MWh (17.303 kWh/day) | 7.794 MWh (21.353 kWh/day) | 1.478 MWh (4.050 kWh/day) |
| Lifetime Since PTO | 37.846 MWh (17.374 kW/day) | 41.741 MWh (19.163 kW/day) | 3.895 MWh (1.788 kW/day) |
| Lifetime Since Install | 37.880 MWh | 42.321 MWh | 4.441 MWh |
| Voltage/Current | 249.7 V / 1.3 A | 249.7 V / 1.0 A | 249.7 V / -0.4 A |
|
|||
| Micro-inverters [pcu_num:5, pcu_level:1] | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Recent Report Data/Time | 04/24/2026 23:59 (24.0 hours) | Number of Devices | 17 set | |||||||
| Current Power | 0.321 kW (0.019 kW/panel) | Today Energy | 37.724 kWh | |||||||
| Group | Serial Number | Model | Status | Power (kW) [Flag] [Comm] | Energy (kWh) [Monthly] | Group | ||||
| Now | Max | Today | Yesterday | 7 days | Average | Total | ||||
| porch | 01 - 202232****** | IQ7+ | [5] VCOP | 0.000 | 0.294 | 2.043 | 1.873 | 10.401 | 0.000 kW 1.966 kWh |
0.000 kW 11.798 kWh |
| 02 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.278 | 1.928 | 1.760 | 9.877 | |||
| 03 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.288 | 2.010 | 1.837 | 10.313 | |||
| 04 - 202232****** | IQ7+ | [5] VC-- | 0.000 | 0.290 | 2.039 | 1.861 | 10.422 | |||
| 05 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.277 | 1.827 | 1.651 | 9.471 | |||
| 06 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.284 | 1.950 | 1.766 | 9.954 | |||
| front | 07 - 202206****** | IQ7+ | [5] VCOP | 0.000 | 0.281 | 1.886 | 1.697 | 9.915 | 0.000 kW 1.932 kWh |
0.000 kW 9.661 kWh |
| 08 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.293 | 1.947 | 1.734 | 9.985 | |||
| 09 - 202217****** | IQ7+ | [5] VCOP | 0.000 | 0.289 | 1.934 | 1.725 | 9.942 | |||
| 10 - 202244****** | IQ7+M | [5] VCOP | 0.000 | 0.284 | 1.931 | 1.750 | 10.169 | |||
| 11 - 202224****** | IQ7+M | [5] VCOP | 0.000 | 0.292 | 1.963 | 1.781 | 10.332 | |||
| back | 12 - 202211****** | IQ7+ | [5] VCOP | 0.000 | 0.245 | 1.862 | 1.803 | 9.320 | 0.000 kW 1.901 kWh |
0.000 kW 7.602 kWh |
| 13 - 202223****** | IQ7+ | [5] VCOP | 0.000 | 0.247 | 1.876 | 1.827 | 9.355 | |||
| 14 - 202216****** | IQ7+ | [5] VCOP | 0.000 | 0.249 | 1.930 | 1.851 | 9.696 | |||
| 15 - 202245****** | IQ7+M | [5] VCOP | 0.000 | 0.250 | 1.934 | 1.854 | 9.724 | |||
| wind | 16 - 202320****** | IQ7XS | [5] VCOP | 0.321 | 0.322 | 7.710 | 7.653 | 24.576 | 0.161 kW 4.331 kWh |
0.321 kW 8.663 kWh |
| 17 - 122214****** | IQ7PD | [0] ---- | 0.000 | 0.151 | 0.952 | 0.901 | 4.578 | |||
|
||||||||||
| Charger History | |||||
|---|---|---|---|---|---|
| Voltage PV | 0.99 V | Voltage Charge | 52.25 V | Current/Power | 0.00 A / 0.000 kW |
| Int/Ext Temp | 28.3 °C / 26.0 °C | Flags | 00/00/00 | Energy Today | 0.000 kWh @ 2026-04-24 23:57 |
|
|||||