Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.517 kW
07/04/2026 16:49 (2229 days) Production Consumption NET Usage
Now 3.278 kW 2.761 kW -0.517 kW
Today 28.510 kWh (1.692 kW) 26.544 kWh (1.575 kW) -1.966 kWh (-0.117 kW)
  - This Week 204.462 kWh (30.511 kWh/day) 228.461 kWh (34.093 kWh/day) 23.999 kWh (3.581 kWh/day)
  - This Month 122.861 kWh (33.190 kWh/day) 154.321 kWh (41.688 kWh/day) 31.460 kWh (8.499 kWh/day)
  - This Year 3.733 MWh (20.209 kWh/day) 3.441 MWh (18.631 kWh/day) -0.292 MWh (-1.579 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 205.553 kWh (29.365 kWh/day) 236.970 kWh (33.853 kWh/day) 31.417 kWh (4.488 kWh/day)
Last 30 Days (06/04/2026) 851.772 kWh (28.392 kWh/day) 825.400 kWh (27.513 kWh/day) -26.372 kWh (-0.879 kWh/day)
Last One Year 6.723 MWh (18.420 kWh/day) 7.745 MWh (21.218 kWh/day) 1.021 MWh (2.798 kWh/day)
Lifetime Since PTO 39.298 MWh (17.625 kW/day) 42.952 MWh (19.264 kW/day) 3.653 MWh (1.639 kW/day)
Lifetime Since Install 39.332 MWh 43.532 MWh 4.200 MWh
Voltage/Current 246.8 V / 13.3 A 246.8 V / 11.2 A 246.8 V / -2.1 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 12/23/2020 21:43 (8.9 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 10.669 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.194 0.757 0.097 0.298 0.000 kW
0.725 kWh
0.000 kW
4.348 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.176 0.695 0.166 0.355
03 - 202224****** IQ7+M [5] VCOP 0.000 0.168 0.682 0.259 0.476
04 - 202232****** IQ7+ [5] VCOP 0.000 0.165 0.666 0.330 0.548
05 - 202244****** IQ7+M [5] VCOP 0.000 0.176 0.753 0.525 1.009
06 - 202245****** IQ7+M [5] VCOP 0.000 0.184 0.795 0.570 1.140
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.240 0.947 0.701 1.395 0.000 kW
0.943 kWh
0.000 kW
4.713 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.238 0.800 0.656 0.817
09 - 202217****** IQ7+ [5] VCOP 0.000 0.246 1.038 0.714 1.774
10 - 202244****** IQ7+M [5] VCOP 0.000 0.240 1.021 0.716 1.881
11 - 202224****** IQ7+M [5] VCOP 0.000 0.236 0.906 0.693 1.196
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.071 0.376 0.324 1.239 0.000 kW
0.402 kWh
0.000 kW
1.608 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.090 0.415 0.359 1.085
14 - 202216****** IQ7+ [5] VCOP 0.000 0.088 0.415 0.361 1.060
15 - 202245****** IQ7+M [5] VCOP 0.000 0.085 0.402 0.352 1.879
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 51.98 V Current/Power 162.28 A (8.435 kW)
Remain Capacity/Energy 193.5 Ah (9.9 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 32.7 % State Of Health 98.5 %
Run Time 2h 26m to full Report Date 2020-12-22 16:35
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.