Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.547 kW
05/16/2026 20:43 (2180 days) Production Consumption NET Usage
Now 0.000 kW 0.547 kW 0.547 kW
Today 32.918 kWh (1.587 kW) 5.169 kWh (0.249 kW) -27.749 kWh (-1.338 kW)
  - This Week 183.741 kWh (26.767 kWh/day) 80.816 kWh (11.773 kWh/day) -102.925 kWh (-14.994 kWh/day)
  - This Month 401.816 kWh (25.329 kWh/day) 197.953 kWh (12.478 kWh/day) -203.863 kWh (-12.851 kWh/day)
  - This Year 2.355 MWh (17.332 kWh/day) 2.258 MWh (16.617 kWh/day) -0.097 MWh (-0.715 kWh/day)
Yesterday 21.295 kWh (0.887 kW) 9.495 kWh (0.396 kW) -11.800 kWh (-0.492 kW)
Last 7 Days 183.741 kWh (26.249 kWh/day) 82.368 kWh (11.767 kWh/day) -101.373 kWh (-14.482 kWh/day)
Last 30 Days (04/16/2026) 687.834 kWh (22.928 kWh/day) 383.509 kWh (12.784 kWh/day) -304.325 kWh (-10.144 kWh/day)
Last One Year 6.356 MWh (17.414 kWh/day) 7.784 MWh (21.326 kWh/day) 1.428 MWh (3.912 kWh/day)
Lifetime Since PTO 37.921 MWh (17.388 kW/day) 41.768 MWh (19.152 kW/day) 3.848 MWh (1.764 kW/day)
Lifetime Since Install 37.954 MWh 42.348 MWh 4.394 MWh
Voltage/Current 248.5 V / 0.0 A 248.5 V / 2.2 A 248.5 V / 2.2 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 08/23/2020 23:45 (13.1 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 26.891 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.298 1.877 1.601 10.621 0.000 kW
1.862 kWh
0.000 kW
11.171 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.853 1.580 10.412
03 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.887 1.603 10.616
04 - 202232****** IQ7+ [0] ---- 0.000 0.298 1.896 1.600 10.659
05 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.814 1.542 9.954
06 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.844 1.573 10.260
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.297 1.881 1.531 10.059 0.000 kW
1.894 kWh
0.000 kW
9.470 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.888 1.583 10.194
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 1.882 1.530 10.043
10 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.908 1.592 10.345
11 - 202224****** IQ7+M [0] ---- 0.000 0.299 1.911 1.605 10.383
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.283 1.578 1.342 9.658 0.000 kW
1.563 kWh
0.000 kW
6.250 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.290 1.508 1.312 9.284
14 - 202216****** IQ7+ [0] ---- 0.000 0.290 1.592 1.346 9.672
15 - 202245****** IQ7+M [0] ---- 0.000 0.280 1.572 1.325 9.508
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_all.png". Check that the process running PHP has enough permission.