Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.417 kW
07/04/2026 21:37 (2229 days) Production Consumption NET Usage
Now 0.225 kW 2.642 kW 2.417 kW
Today 32.881 kWh (1.519 kW) 40.715 kWh (1.881 kW) 7.834 kWh (0.362 kW)
  - This Week 208.833 kWh (30.262 kWh/day) 242.632 kWh (35.159 kWh/day) 33.799 kWh (4.898 kWh/day)
  - This Month 127.232 kWh (32.611 kWh/day) 168.492 kWh (43.186 kWh/day) 41.260 kWh (10.575 kWh/day)
  - This Year 3.737 MWh (20.211 kWh/day) 3.455 MWh (18.687 kWh/day) -0.282 MWh (-1.524 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 208.833 kWh (29.833 kWh/day) 244.555 kWh (34.936 kWh/day) 35.722 kWh (5.103 kWh/day)
Last 30 Days (06/04/2026) 850.637 kWh (28.355 kWh/day) 828.103 kWh (27.603 kWh/day) -22.534 kWh (-0.751 kWh/day)
Last One Year 6.723 MWh (18.420 kWh/day) 7.749 MWh (21.231 kWh/day) 1.026 MWh (2.812 kWh/day)
Lifetime Since PTO 39.303 MWh (17.625 kW/day) 42.966 MWh (19.268 kW/day) 3.663 MWh (1.643 kW/day)
Lifetime Since Install 39.337 MWh 43.546 MWh 4.209 MWh
Voltage/Current 249.2 V / 0.9 A 249.0 V / 10.6 A 249.1 V / 9.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/29/2020 22:33 (10.5 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 4.434 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.103 0.308 1.102 8.629 0.000 kW
0.305 kWh
0.000 kW
1.833 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.099 0.304 1.094 8.647
03 - 202224****** IQ7+M [0] ---- 0.000 0.114 0.311 1.113 8.583
04 - 202232****** IQ7+ [0] ---- 0.000 0.106 0.307 1.108 8.615
05 - 202244****** IQ7+M [0] ---- 0.000 0.099 0.299 1.095 8.529
06 - 202245****** IQ7+M [0] ---- 0.000 0.096 0.304 1.092 8.527
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.087 0.274 1.194 9.049 0.000 kW
0.276 kWh
0.000 kW
1.381 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.084 0.274 1.195 8.572
09 - 202217****** IQ7+ [0] ---- 0.000 0.100 0.277 1.193 9.016
10 - 202244****** IQ7+M [0] ---- 0.000 0.096 0.279 1.211 9.071
11 - 202224****** IQ7+M [0] ---- 0.000 0.093 0.277 1.207 9.028
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.111 0.302 0.758 6.667 0.000 kW
0.305 kWh
0.000 kW
1.220 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.118 0.304 0.744 6.561
14 - 202216****** IQ7+ [0] ---- 0.000 0.113 0.310 0.773 6.706
15 - 202245****** IQ7+M [0] ---- 0.000 0.105 0.304 0.760 6.692
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.02 V Current/Power 175.06 A (9.807 kW)
Remain Capacity/Energy 568.5 Ah (29.1 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 96.2 % State Of Health 98.5 %
Run Time 7m to full Report Date 2020-09-29 23:14
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.