Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Exporting to grid by 0.156 kW
03/13/2026 07:02 (2116 days) Production Consumption NET Usage
Now 0.316 kW 0.160 kW -0.156 kW
Today 2.242 kWh (0.317 kW) 2.726 kWh (0.385 kW) 0.484 kWh (0.068 kW)
  - This Week 88.525 kWh (16.723 kWh/day) 72.021 kWh (13.605 kWh/day) -16.504 kWh (-3.118 kWh/day)
  - This Month 182.233 kWh (14.823 kWh/day) 178.320 kWh (14.505 kWh/day) -3.913 kWh (-0.318 kWh/day)
  - This Year 0.816 MWh (11.448 kWh/day) 1.278 MWh (17.928 kWh/day) 0.462 MWh (6.480 kWh/day)
Yesterday 10.309 kWh (0.430 kW) 12.404 kWh (0.517 kW) 2.095 kWh (0.087 kW)
Last 7 Days 98.360 kWh (14.051 kWh/day) 103.128 kWh (14.733 kWh/day) 4.768 kWh (0.681 kWh/day)
Last 30 Days (02/11/2026) 390.751 kWh (13.025 kWh/day) 500.417 kWh (16.681 kWh/day) 109.666 kWh (3.656 kWh/day)
Last One Year 6.046 MWh (16.564 kWh/day) 7.828 MWh (21.447 kWh/day) 1.782 MWh (4.883 kWh/day)
Lifetime Since PTO 36.382 MWh (17.191 kW/day) 40.789 MWh (19.274 kW/day) 4.407 MWh (2.082 kW/day)
Lifetime Since Install 36.416 MWh 41.369 MWh 4.953 MWh
Voltage/Current 249.4 V / 1.3 A 249.4 V / 0.6 A 249.4 V / -0.6 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/08/2020 20:42 (14.8 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 34.409 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.297 2.439 2.109 11.255 0.000 kW
2.327 kWh
0.000 kW
13.959 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.296 2.344 2.033 10.861
03 - 202224****** IQ7+M [0] ---- 0.000 0.297 2.323 2.008 10.841
04 - 202232****** IQ7+ [0] ---- 0.000 0.297 2.346 2.031 10.877
05 - 202244****** IQ7+M [0] ---- 0.000 0.296 2.130 1.808 10.002
06 - 202245****** IQ7+M [0] ---- 0.000 0.296 2.378 2.064 10.989
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.296 2.090 1.842 9.844 0.000 kW
2.165 kWh
0.000 kW
10.824 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 2.197 1.877 10.086
09 - 202217****** IQ7+ [0] ---- 0.000 0.296 2.129 1.861 10.036
10 - 202244****** IQ7+M [0] ---- 0.000 0.296 2.200 1.886 10.202
11 - 202224****** IQ7+M [0] ---- 0.000 0.296 2.208 1.896 10.193
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.280 2.449 2.247 11.574 0.000 kW
2.406 kWh
0.000 kW
9.626 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.279 2.363 2.198 11.321
14 - 202216****** IQ7+ [0] ---- 0.000 0.279 2.433 2.246 11.588
15 - 202245****** IQ7+M [0] ---- 0.000 0.273 2.381 2.202 11.391
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.03 V Current/Power 175.10 A (9.812 kW)
Remain Capacity/Energy 568.5 Ah (29.1 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 98.5 % State Of Health 96.2 %
Run Time 2m to full Report Date 2020-06-08 23:32
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

Voltage 56.03 V Cell (MIN/MAX) 3.495 V / 3.506 V (0.011 V)
Current/Power 0.00 A (0 W) Runtime Stand-by
Remain Capacity/Energy 189.5 Ah (9.7 kWh) Full Capacity/Energy 192.4 Ah (9.9 kWh)
State Of Charge 98.5 % State Of Health 96.2 %
Temperature 24.0 °C Cycle 22
MOSFET CFET = ON, DFET = ON Reported 2020-06-08 23:32
Cell #01 Cell #02 Cell #03 Cell #04 Cell #05 Cell #06 Cell #07 Cell #08
3.495 V 3.501 V 3.496 V 3.502 V 3.504 V 3.502 V 3.499 V 3.506 V
Cell #09 Cell #10 Cell #11 Cell #12 Cell #13 Cell #14 Cell #15 Cell #16
3.501 V 3.499 V 3.501 V 3.505 V 3.503 V 3.502 V 3.506 V 3.504 V
pack voltage and current cell voltages
pack temperature
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -
Voltage - Cell (MIN/MAX) - / -
Current/Power - Runtime -
Remain Capacity/Energy - Full Capacity/Energy -
State Of Charge - State Of Health -
Temperature - Cycle -
MOSFET - Reported -