Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.237 kW
07/04/2026 22:47 (2229 days) Production Consumption NET Usage
Now 0.226 kW 0.463 kW 0.237 kW
Today 33.145 kWh (1.453 kW) 42.232 kWh (1.851 kW) 9.087 kWh (0.398 kW)
  - This Week 209.097 kWh (30.088 kWh/day) 244.149 kWh (35.132 kWh/day) 35.052 kWh (5.044 kWh/day)
  - This Month 127.496 kWh (32.276 kWh/day) 170.009 kWh (43.039 kWh/day) 42.513 kWh (10.762 kWh/day)
  - This Year 3.737 MWh (20.207 kWh/day) 3.457 MWh (18.690 kWh/day) -0.281 MWh (-1.517 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 209.097 kWh (29.871 kWh/day) 244.969 kWh (34.996 kWh/day) 35.872 kWh (5.125 kWh/day)
Last 30 Days (06/04/2026) 850.540 kWh (28.351 kWh/day) 829.086 kWh (27.636 kWh/day) -21.454 kWh (-0.715 kWh/day)
Last One Year 6.723 MWh (18.420 kWh/day) 7.747 MWh (21.226 kWh/day) 1.024 MWh (2.805 kWh/day)
Lifetime Since PTO 39.303 MWh (17.625 kW/day) 42.968 MWh (19.268 kW/day) 3.665 MWh (1.643 kW/day)
Lifetime Since Install 39.337 MWh 43.548 MWh 4.211 MWh
Voltage/Current 249.3 V / 0.9 A 249.3 V / 1.9 A 249.3 V / 1.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/09/2020 23:22 (12.3 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 16.860 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.281 1.169 1.799 10.982 0.000 kW
1.160 kWh
0.000 kW
6.957 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.285 1.160 1.785 10.871
03 - 202224****** IQ7+M [0] ---- 0.000 0.277 1.180 1.822 11.073
04 - 202232****** IQ7+ [0] ---- 0.000 0.280 1.171 1.820 11.051
05 - 202244****** IQ7+M [0] ---- 0.000 0.283 1.132 1.737 10.546
06 - 202245****** IQ7+M [0] ---- 0.000 0.284 1.145 1.730 10.540
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.292 1.148 1.856 10.927 0.000 kW
1.150 kWh
0.000 kW
5.751 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.289 1.131 1.809 10.659
09 - 202217****** IQ7+ [0] ---- 0.000 0.281 1.143 1.831 10.847
10 - 202244****** IQ7+M [0] ---- 0.000 0.286 1.170 1.898 11.141
11 - 202224****** IQ7+M [0] ---- 0.000 0.289 1.160 1.894 11.114
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.223 1.035 1.514 9.589 0.000 kW
1.038 kWh
0.000 kW
4.151 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.220 1.031 1.474 9.395
14 - 202216****** IQ7+ [0] ---- 0.000 0.222 1.050 1.523 9.622
15 - 202245****** IQ7+M [0] ---- 0.000 0.219 1.036 1.502 9.473
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.