Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.639 kW
07/04/2026 20:47 (2229 days) Production Consumption NET Usage
Now 0.226 kW 0.865 kW 0.639 kW
Today 32.693 kWh (1.571 kW) 38.470 kWh (1.848 kW) 5.777 kWh (0.278 kW)
  - This Week 208.645 kWh (30.387 kWh/day) 240.387 kWh (35.010 kWh/day) 31.742 kWh (4.623 kWh/day)
  - This Month 127.044 kWh (32.855 kWh/day) 166.247 kWh (42.993 kWh/day) 39.203 kWh (10.138 kWh/day)
  - This Year 3.737 MWh (20.214 kWh/day) 3.453 MWh (18.679 kWh/day) -0.284 MWh (-1.535 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 208.645 kWh (29.806 kWh/day) 243.598 kWh (34.800 kWh/day) 34.953 kWh (4.993 kWh/day)
Last 30 Days (06/04/2026) 850.711 kWh (28.357 kWh/day) 827.715 kWh (27.591 kWh/day) -22.996 kWh (-0.767 kWh/day)
Last One Year 6.723 MWh (18.419 kWh/day) 7.748 MWh (21.228 kWh/day) 1.025 MWh (2.809 kWh/day)
Lifetime Since PTO 39.303 MWh (17.626 kW/day) 42.964 MWh (19.267 kW/day) 3.661 MWh (1.642 kW/day)
Lifetime Since Install 39.336 MWh 43.544 MWh 4.207 MWh
Voltage/Current 250.8 V / 0.9 A 250.7 V / 3.5 A 250.7 V / 2.5 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 09/01/2020 23:31 (12.4 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 10.494 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.297 0.732 1.065 10.442 0.000 kW
0.727 kWh
0.000 kW
4.361 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.295 0.724 1.054 10.288
03 - 202224****** IQ7+M [0] ---- 0.000 0.288 0.737 1.074 10.483
04 - 202232****** IQ7+ [0] ---- 0.000 0.295 0.729 1.062 10.479
05 - 202244****** IQ7+M [0] ---- 0.000 0.296 0.716 1.002 9.982
06 - 202245****** IQ7+M [0] ---- 0.000 0.297 0.724 1.026 10.115
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.295 0.700 1.002 10.123 0.000 kW
0.704 kWh
0.000 kW
3.518 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.295 0.700 0.977 10.122
09 - 202217****** IQ7+ [0] ---- 0.000 0.287 0.704 1.008 10.104
10 - 202244****** IQ7+M [0] ---- 0.000 0.293 0.710 1.022 10.361
11 - 202224****** IQ7+M [0] ---- 0.000 0.291 0.704 1.012 10.347
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.225 0.650 0.982 9.247 0.000 kW
0.654 kWh
0.000 kW
2.615 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.223 0.646 0.981 9.040
14 - 202216****** IQ7+ [0] ---- 0.000 0.227 0.665 0.998 9.270
15 - 202245****** IQ7+M [0] ---- 0.000 0.229 0.654 0.986 9.118
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VC-- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 57.62 V Current/Power 179.92 A (10.366 kW)
Remain Capacity/Energy 589.2 Ah (30.2 kWh) Full Capacity/Energy 591.0 Ah (30.3 kWh)
State Of Charge 99.7 % State Of Health 98.5 %
Run Time - to full Report Date 2020-09-01 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.