Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 0.243 kW
05/16/2026 23:17 (2180 days) Production Consumption NET Usage
Now 0.000 kW 0.243 kW 0.243 kW
Today 32.918 kWh (1.413 kW) 6.545 kWh (0.281 kW) -26.373 kWh (-1.132 kW)
  - This Week 183.741 kWh (26.358 kWh/day) 82.192 kWh (11.790 kWh/day) -101.549 kWh (-14.567 kWh/day)
  - This Month 401.816 kWh (25.160 kWh/day) 199.329 kWh (12.481 kWh/day) -202.487 kWh (-12.679 kWh/day)
  - This Year 2.355 MWh (17.319 kWh/day) 2.259 MWh (16.614 kWh/day) -0.096 MWh (-0.705 kWh/day)
Yesterday 21.295 kWh (0.887 kW) 9.495 kWh (0.396 kW) -11.800 kWh (-0.492 kW)
Last 7 Days 183.741 kWh (26.249 kWh/day) 82.421 kWh (11.774 kWh/day) -101.320 kWh (-14.474 kWh/day)
Last 30 Days (04/16/2026) 687.834 kWh (22.928 kWh/day) 383.117 kWh (12.771 kWh/day) -304.717 kWh (-10.157 kWh/day)
Last One Year 6.356 MWh (17.414 kWh/day) 7.783 MWh (21.323 kWh/day) 1.427 MWh (3.909 kWh/day)
Lifetime Since PTO 37.921 MWh (17.387 kW/day) 41.770 MWh (19.152 kW/day) 3.849 MWh (1.765 kW/day)
Lifetime Since Install 37.954 MWh 42.350 MWh 4.395 MWh
Voltage/Current 249.5 V / 0.0 A 249.4 V / 1.0 A 249.5 V / 1.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 06/23/2020 20:35 (14.7 hours) Number of Devices 17 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 32.075 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.296 2.248 2.004 13.361 0.000 kW
2.169 kWh
0.000 kW
13.015 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.297 2.175 1.930 12.952
03 - 202224****** IQ7+M [0] ---- 0.000 0.298 2.172 1.910 12.887
04 - 202232****** IQ7+ [0] ---- 0.000 0.296 2.197 1.930 12.987
05 - 202244****** IQ7+M [0] ---- 0.000 0.297 2.007 1.724 11.795
06 - 202245****** IQ7+M [0] ---- 0.000 0.298 2.215 1.966 13.129
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.298 1.969 1.717 11.716 0.000 kW
2.042 kWh
0.000 kW
10.208 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.297 2.059 1.815 12.092
09 - 202217****** IQ7+ [0] ---- 0.000 0.294 2.019 1.775 11.933
10 - 202244****** IQ7+M [0] ---- 0.000 0.292 2.078 1.834 12.182
11 - 202224****** IQ7+M [0] ---- 0.000 0.296 2.082 1.841 12.198
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.272 2.230 2.038 13.712 0.000 kW
2.213 kWh
0.000 kW
8.851 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.273 2.165 1.958 13.405
14 - 202216****** IQ7+ [0] ---- 0.000 0.275 2.245 2.042 13.782
15 - 202245****** IQ7+M [0] ---- 0.000 0.276 2.212 2.000 13.551
wind 16 - 202320****** IQ7XS [5] VCOP 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 56.01 V Current/Power 174.96 A (9.800 kW)
Remain Capacity/Energy 516.6 Ah (26.4 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 89.5 % State Of Health 96.2 %
Run Time 20m to full Report Date 2020-06-23 23:40
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack