Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.705 kW
07/01/2026 19:04 (2226 days) Production Consumption NET Usage
Now 0.351 kW 3.056 kW 2.705 kW
Today 25.413 kWh (1.331 kW) 31.290 kWh (1.639 kW) 5.877 kWh (0.308 kW)
  - This Week 107.014 kWh (28.199 kWh/day) 105.430 kWh (27.782 kWh/day) -1.584 kWh (-0.417 kWh/day)
  - This Month 25.413 kWh (31.946 kWh/day) 31.290 kWh (39.334 kWh/day) 5.877 kWh (7.388 kWh/day)
  - This Year 3.635 MWh (19.996 kWh/day) 3.318 MWh (18.252 kWh/day) -0.317 MWh (-1.745 kWh/day)
Yesterday 26.873 kWh (1.121 kW) 21.329 kWh (0.889 kW) -5.544 kWh (-0.231 kW)
Last 7 Days 164.914 kWh (23.559 kWh/day) 167.002 kWh (23.857 kWh/day) 2.088 kWh (0.298 kWh/day)
Last 30 Days (06/01/2026) 866.513 kWh (28.884 kWh/day) 741.030 kWh (24.701 kWh/day) -125.483 kWh (-4.183 kWh/day)
Last One Year 6.699 MWh (18.354 kWh/day) 7.724 MWh (21.160 kWh/day) 1.024 MWh (2.806 kWh/day)
Lifetime Since PTO 39.201 MWh (17.604 kW/day) 42.829 MWh (19.233 kW/day) 3.628 MWh (1.629 kW/day)
Lifetime Since Install 39.235 MWh 43.409 MWh 4.174 MWh
Voltage/Current 246.5 V / 1.4 A 246.3 V / 12.4 A 246.4 V / 11.0 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 11/26/2025 23:46 (9.6 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 3.024 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [5] VCOP 0.000 0.084 0.213 0.281 3.857 0.000 kW
0.206 kWh
0.000 kW
1.234 kWh
02 - 202244****** IQ7+M [5] VCOP 0.000 0.084 0.200 0.269 3.683
03 - 202224****** IQ7+M [5] VCOP 0.000 0.084 0.212 0.281 3.843
04 - 202232****** IQ7+ [5] VCOP 0.000 0.086 0.211 0.280 3.865
05 - 202244****** IQ7+M [5] VCOP 0.000 0.081 0.196 0.261 3.688
06 - 202245****** IQ7+M [5] VCOP 0.000 0.084 0.204 0.275 3.779
front 07 - 202206****** IQ7+ [5] VCOP 0.000 0.092 0.198 0.264 4.147 0.000 kW
0.199 kWh
0.000 kW
0.996 kWh
08 - 202245****** IQ7+M [5] VCOP 0.000 0.096 0.199 0.267 4.366
09 - 202217****** IQ7+ [5] VCOP 0.000 0.096 0.198 0.269 4.484
10 - 202244****** IQ7+M [5] VCOP 0.000 0.092 0.201 0.270 4.472
11 - 202224****** IQ7+M [5] VCOP 0.000 0.097 0.199 0.262 4.417
back 12 - 202211****** IQ7+ [5] VCOP 0.000 0.054 0.185 0.249 2.087 0.000 kW
0.199 kWh
0.000 kW
0.794 kWh
13 - 202223****** IQ7+ [5] VCOP 0.000 0.058 0.195 0.263 2.331
14 - 202216****** IQ7+ [5] VCOP 0.000 0.059 0.207 0.290 2.476
15 - 202245****** IQ7+M [5] VCOP 0.000 0.059 0.207 0.289 2.447
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [5] VCOP 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [0] ---- 0.000 0.000 0.000 0.000 1.637
Panel Layout Each Group Production

Charger History
Voltage PV 1.25 V Voltage Charge 52.34 V Current/Power 0.00 A / 0.000 kW
Int/Ext Temp 27.5 °C / 24.3 °C Flags 00/00/00 Energy Today 0.000 kWh @ 2025-11-26 23:59
voltage in/out power and energy internal/external temperature

Battery History
Voltage 52.51 V Current/Power -1.50 A (-78 W)
Remain Capacity/Energy 234.9 Ah (12.0 kWh) Full Capacity/Energy 593.1 Ah (30.4 kWh)
State Of Charge 39.6 % State Of Health 98.9 %
Run Time 6d 12h 36m to empty Report Date 2025-11-26 23:54
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_batt2_0.png". Check that the process running PHP has enough permission.