Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 1.177 kW
07/04/2026 22:48 (2229 days) Production Consumption NET Usage
Now 0.226 kW 1.403 kW 1.177 kW
Today 33.149 kWh (1.452 kW) 42.252 kWh (1.851 kW) 9.103 kWh (0.399 kW)
  - This Week 209.101 kWh (30.085 kWh/day) 244.169 kWh (35.131 kWh/day) 35.068 kWh (5.046 kWh/day)
  - This Month 127.500 kWh (32.271 kWh/day) 170.029 kWh (43.036 kWh/day) 42.529 kWh (10.764 kWh/day)
  - This Year 3.737 MWh (20.207 kWh/day) 3.457 MWh (18.690 kWh/day) -0.281 MWh (-1.517 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 209.101 kWh (29.872 kWh/day) 244.989 kWh (34.998 kWh/day) 35.888 kWh (5.127 kWh/day)
Last 30 Days (06/04/2026) 850.544 kWh (28.351 kWh/day) 829.106 kWh (27.637 kWh/day) -21.438 kWh (-0.715 kWh/day)
Last One Year 6.723 MWh (18.420 kWh/day) 7.747 MWh (21.226 kWh/day) 1.024 MWh (2.805 kWh/day)
Lifetime Since PTO 39.303 MWh (17.625 kW/day) 42.968 MWh (19.268 kW/day) 3.665 MWh (1.643 kW/day)
Lifetime Since Install 39.337 MWh 43.548 MWh 4.211 MWh
Voltage/Current 249.5 V / 0.9 A 249.4 V / 5.6 A 249.4 V / 4.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/25/2020 23:29 (14.3 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 25.071 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.297 1.742 0.969 12.591 0.000 kW
1.673 kWh
0.000 kW
10.039 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.297 1.681 0.957 12.235
03 - 202224****** IQ7+M [0] ---- 0.000 0.297 1.684 0.977 12.311
04 - 202232****** IQ7+ [0] ---- 0.000 0.296 1.710 0.965 12.358
05 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.527 0.949 11.451
06 - 202245****** IQ7+M [0] ---- 0.000 0.297 1.695 0.953 12.293
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.297 1.537 0.900 11.291 0.000 kW
1.568 kWh
0.000 kW
7.841 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.296 1.577 0.906 11.595
09 - 202217****** IQ7+ [0] ---- 0.000 0.295 1.551 0.913 11.418
10 - 202244****** IQ7+M [0] ---- 0.000 0.296 1.592 0.919 11.677
11 - 202224****** IQ7+M [0] ---- 0.000 0.298 1.584 0.914 11.666
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.284 1.814 0.897 12.031 0.000 kW
1.798 kWh
0.000 kW
7.192 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.284 1.763 0.898 11.689
14 - 202216****** IQ7+ [0] ---- 0.000 0.281 1.816 0.914 12.056
15 - 202245****** IQ7+M [0] ---- 0.000 0.277 1.799 0.899 11.862
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Battery History
Voltage 55.63 V Current/Power 174.77 A (9.723 kW)
Remain Capacity/Energy 577.2 Ah (29.6 kWh) Full Capacity/Energy 577.2 Ah (29.6 kWh)
State Of Charge 100.0 % State Of Health 96.2 %
Run Time - to full Report Date 2020-07-25 23:59
voltag, current for each battery pack voltage, current, and SOC temperature for each battery pack

JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.