Date Offset  [+30][+10][+05][+01][-01][-05][-10][-30]

Importing from grid by 2.418 kW
07/04/2026 21:51 (2229 days) Production Consumption NET Usage
Now 0.226 kW 2.644 kW 2.418 kW
Today 32.936 kWh (1.505 kW) 41.071 kWh (1.876 kW) 8.135 kWh (0.372 kW)
  - This Week 208.888 kWh (30.225 kWh/day) 242.988 kWh (35.160 kWh/day) 34.100 kWh (4.934 kWh/day)
  - This Month 127.287 kWh (32.541 kWh/day) 168.848 kWh (43.166 kWh/day) 41.561 kWh (10.625 kWh/day)
  - This Year 3.737 MWh (20.210 kWh/day) 3.456 MWh (18.688 kWh/day) -0.281 MWh (-1.522 kWh/day)
Yesterday 33.078 kWh (1.378 kW) 41.779 kWh (1.741 kW) 8.701 kWh (0.363 kW)
Last 7 Days 208.888 kWh (29.841 kWh/day) 244.548 kWh (34.935 kWh/day) 35.660 kWh (5.094 kWh/day)
Last 30 Days (06/04/2026) 850.616 kWh (28.354 kWh/day) 828.340 kWh (27.611 kWh/day) -22.276 kWh (-0.743 kWh/day)
Last One Year 6.723 MWh (18.420 kWh/day) 7.749 MWh (21.231 kWh/day) 1.026 MWh (2.811 kWh/day)
Lifetime Since PTO 39.303 MWh (17.625 kW/day) 42.966 MWh (19.268 kW/day) 3.664 MWh (1.643 kW/day)
Lifetime Since Install 39.337 MWh 43.546 MWh 4.210 MWh
Voltage/Current 249.3 V / 0.9 A 249.3 V / 10.6 A 249.3 V / 9.7 A
Meter Accumulated Grid Votlage Power

Micro-inverters [pcu_num:0, pcu_level:0]
Recent Report Data/Time 07/14/2020 22:51 (14.4 hours) Number of Devices 18 set
Current Power 0.000 kW (0.000 kW/panel) Today Energy 32.311 kWh
Group Serial Number Model Status Power (kW) [Flag] [Comm] Energy (kWh) [Monthly] Group
Now Max Today Yesterday 7 days Average Total
porch 01 - 202232****** IQ7+ [0] ---- 0.000 0.298 2.270 2.232 10.456 0.000 kW
2.176 kWh
0.000 kW
13.055 kWh
02 - 202244****** IQ7+M [0] ---- 0.000 0.301 2.188 2.158 10.170
03 - 202224****** IQ7+M [0] ---- 0.000 0.300 2.182 2.159 10.223
04 - 202232****** IQ7+ [0] ---- 0.000 0.298 2.202 2.166 10.238
05 - 202244****** IQ7+M [0] ---- 0.000 0.299 2.000 1.999 9.573
06 - 202245****** IQ7+M [0] ---- 0.000 0.297 2.214 2.178 10.241
front 07 - 202206****** IQ7+ [0] ---- 0.000 0.300 1.972 1.954 9.211 0.000 kW
2.045 kWh
0.000 kW
10.224 kWh
08 - 202245****** IQ7+M [0] ---- 0.000 0.298 2.071 2.049 9.537
09 - 202217****** IQ7+ [0] ---- 0.000 0.297 2.013 1.990 9.383
10 - 202244****** IQ7+M [0] ---- 0.000 0.299 2.083 2.059 9.643
11 - 202224****** IQ7+M [0] ---- 0.000 0.298 2.085 2.070 9.627
back 12 - 202211****** IQ7+ [0] ---- 0.000 0.294 2.302 2.183 10.405 0.000 kW
2.258 kWh
0.000 kW
9.032 kWh
13 - 202223****** IQ7+ [0] ---- 0.000 0.294 2.209 2.085 10.129
14 - 202216****** IQ7+ [0] ---- 0.000 0.292 2.282 2.166 10.432
15 - 202245****** IQ7+M [0] ---- 0.000 0.286 2.239 2.126 10.281
wind 16 - 202320****** IQ7XS [0] ---- 0.000 0.000 0.000 0.000 0.000 0.000 kW
0.000 kWh
0.000 kW
0.000 kWh
17 - 122344****** IQ7AS [0] ---- 0.000 0.000 0.000 0.000 0.000
18 - 122214****** IQ7PD [5] VCOP 0.000 0.000 0.000 0.000 0.000
Panel Layout Each Group Production

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224

Warning: array_push() expects parameter 1 to be array, null given in C:\wamp64\www\solar\status_battery_inc.php on line 224
JpGraph Error: 25107 Can't write to file "images/chart_battery_summary_temperature.png". Check that the process running PHP has enough permission.